Ii – 8 specifications f o r – HEIDENHAIN ND 287 User Manual User Manual
Page 139

ND 287
139
II – 8 Specifications f
o
r
Data interface
Two serial interfaces:
RS-232-C/V.24
110 to 115 200 baud
USB Type B
(UART)
You can use only one interface for data transfer at a time. The data transfer
software TNCremo is available for free on the HEIDENHAIN website at
Information
.
Optional accessories
Encoder module for connecting a HEIDENHAIN encoder with 11 µApp, 1 Vpp
or EnDat interface (purely serial) for a second axis X2
Analog module as input assembly X1 and/or X2
for connecting an analog
sensor with ±10 V interface, 24 V supply voltage, preferably a temperature
sensor for axis-error compensation
Ethernet module (100baseT) for network connection via TCP/IP protocol
Mounting base for installation in a 19-inch electrical cabinet
Adapter cables with D-sub connector for HEIDENHAIN encoders
Length gauge with D-sub connector
Data transmission cable for RS-232-C/V.24 interface
Data transmission cable for USB interface
Power connection
100 V~ to 240 V~; 50 Hz to 60 Hz
Line fuse
2 x T500 mA
Power
Max. 30 VA
Electromagnetic compatibility
/
CE compliance
The encoder fulfills the requirements for electromagnetic compatibility according
to 2004/108/EEC with respect to the generic standards for
Noise immunity (IEC 61000-6-2)
Emission (IEC 61000-6-4)
Operating temperature
0 °C to 50 °C (32 °F to 122 °F)
Storage temperature
–40 °C to 85 °C (–40 °F to 185 °F)
Relative air humidity
Annual mean: < 75 %
In exceptional cases: < 90 %
Protection
(IEC 60529)
IP 40 rear panel, IP 54 front panel
Weight
Approx. 2.5 kg (5.5 lb.)
Housing
Benchtop design, cast-metal housing
Housing dimensions
Width: 211 mm, height: 112 mm (including feet), depth: 251 mm (including
connector)
Specifications