beautypg.com

HEIDENHAIN ND 287 User Manual User Manual

Page 133

background image

ND 287

133

II – 7 Input and output of par

a

met

e

r list and er

ro

r

compensation table

ND 287 with two linear encoders connected to inputs X1 and X2
(optional)

Parameter

Meaning

#

Start character (#)

ND-287 2 MM

Model: ND-287, unit of measure MM or IN (inches)

AXIS X1

=

0

Axis to be compensated

X1 FCT X1

=

0

Error-causing axis

SPACING X1

= +

10.0000

Point spacing: 10 mm (value input)

DATUM X1

= +

0.0000

Datum: 0 mm (value input)

COMP.NO. 000

= +

0.0000 = +

0.0000

Compensation value 0 = 0.0000 mm

(Compensation value 0 is always 0.0000 mm.)

COMP.NO. 001

= +

10.0000 =

...

Compensation value 1 = No value entered

COMP.NO. 002

= +

20.0000 =

...

Compensation values 2 - 199 = No values entered
Axis will not be compensated

.

COMP.NO. 003

= + 30.0000 =

...

COMP.NO. 004

= + 40.0000 =

...

COMP.NO. 005

= + 50.0000 =

...

COMP.NO. 006

= + 60.0000 =

...

COMP.NO. 007

= + 70.0000 =

...

COMP.NO. 008

= + 80.0000 =

...

COMP.NO. 009

= + 90.0000 =

...

COMP.NO. 010

= + 100.0000 =

...

COMP.NO. 011

= + 110.0000 =

...

COMP.NO. 012

= + 120.0000 =

...

COMP.NO. 013

= + 130.0000 =

...

COMP.NO. 014

= + 140.0000 =

...

COMP.NO. 015

= + 150.0000 =

...

COMP.NO. 016

= + 160.0000 =

...

COMP.NO. 017

= + 170.0000 =

...

COMP.NO. 018

= + 180.0000 =

...

...

COMP.NO. 190

= + 1900.0000 =

...

COMP.NO. 191

= + 1910.0000 =

...

This manual is related to the following products: