Ii – 2 installation set u p – HEIDENHAIN ND 287 User Manual User Manual

Page 82

background image

82

II Installation, specifications

II – 2 Installation Set

u

p

Creating an error compensation table

To start a new error compensation table, first press the EDIT TABLE

soft key. This opens the ERROR COMPENSATION TABLE form.

It may occur that the error is not caused by the axis to be

compensated. Press the X1/X2 soft key to select the appropriate

axis in the ERROR-CAUSING AXIS field.

All correction points (up to 200) are equally spaced from the start

point. Enter the distance between each of the correction points.

Select POINT SPACING and press the SPACING soft key or the

ENTER key. Enter a value and press ENTER.

Enter the START point:

If the start point is known, enter the start point. Select START

POINT and press the START POINT soft key or the ENTER key.

The start point is measured from the scale's reference point.

If the start point is not known, move to the location of the start

point. Please keep in mind that the reference marks must have

been crossed. Press the TEACH POSITION soft key. Press the

ENTER key to confirm the position.

In the REF DISPLAY field, the ND shows the current value of the
axis to be compensated

without considering the datums entered.

Fig. II.33 Error compensation table

Fig. II.34 Error compensation table

Fig. II.35 Error compensation table: Enter the START

point.

After a new start point has been entered, the ND 287 will

adjust the previous values in the error compensation table.