HEIDENHAIN ND 287 User Manual User Manual
Page 123
![background image](https://www.manualsdir.com/files/815450/content/doc123.png)
ND 287
123
II – 7 Input and output of par
a
met
e
r list and er
ro
r
compensation table
ND 287 with two rotary encoders connected to inputs X1 and X2
(optional)
Parameter
Meaning
#
Start character (#)
ND-287 2
DEG
Model: ND-287, Unit of measure: DEG, DMS or rad
P01
LINEAR =
0
Unit of measure for linear dimensions: mm = 0, inches = 1
P02
ANGULAR =
0
Unit of measure for angular dimensions: DEG = 0, DMS = 1, rad = 2
P03.1 ENC. TYPE =
1
X1: Encoder type: linear = 0, rotary = 1
P03.2 ENC. TYPE =
1
X2: Encoder type: linear = 0, rotary = 1
P04.1 ENC. SIGNAL =
1
X1: Encoder signal: 0 = 11 µA, 1 = 1 Vpp, 2 = Endat, 3 = ANALOG
P04.2 ENC. SIGNAL =
1
X2: Encoder signal: 0 = 11 µA, 1 = 1 Vpp, 2 = Endat, 3 = ANALOG
P05
AXES DISPL. =
0
Display: 0 = X1, 1 = X2, 2 = X1 + X2, 3 = X1 - X2, 4 = f(X1,X2)
P06.1
ANGLE =
0
X1: Angle format: 0 = +/– 180°, 1 = 360° , 2 = +/– infinity
P06.2
ANGLE =
0
X2: Angle format: 0 = +/– 180°, 1 = 360° , 2 = +/– infinity
P10.1 SCALING =
0
X1: Scaling: 0 = off, 1 = on
P10.2 SCALING =
0
X2: Scaling: 0 = off, 1 = on
P11.1 SCL. FACTOR = + 1.000000
X1: Scale factor = 1.000000 (default setting)
P11.2 SCL. FACTOR = + 1.000000
X2: Scale factor = 1.000000 (default setting)
P20 BRIGHTNESS =
94
Brightness of LCD screen: 0 - 100 % (80 % is the default setting)
P21
DISP. SAVER =
1
Screen saver: 0 = off, 1 = on
P22 SAVER TIME =
120
Idle time before screen saver is activated: 120 min
P23 START.DISPL. =
1
Power-up screen: 0 = off, 1 = on
P24
SOFTKEY.X12 =
10101
Display mode selectable with SOFTKEY X1/X2: 11111 = all activated
P30.1 DIRECTION =
0
X1: Count direction: 0 = positive, 1 = negative
P30.2 DIRECTION =
0
X2: Count direction: 0 = positive, 1 = negative
P31.1 SIGN.PERIOD =
20
X1: Signal period: 20 µm (10 µm is the default setting)
P31.2 SIGN.PERIOD =
20
X2: Signal period: 20 µm (10 µm is the default setting)
P32.1
SP/R =
36000
X1: Signal periods per revolution: 36000 is the default setting
P32.2
SP/R =
36000
X2: Signal periods per revolution: 36000 is the default setting
P33.1 COUNT MODE =
5
X1: Counting mode: 0 - 5 = 5, 0 - 2 = 2, 0 - 1 = 1
P33.2 COUNT MODE =
5
X2: Counting mode: 0 - 5 = 5, 0 - 2 = 2, 0 - 1 = 1