HEIDENHAIN ND 287 User Manual User Manual
Page 124
![background image](https://www.manualsdir.com/files/815450/content/doc124.png)
124
II Installation, specifications
II – 7 Input and output of par
a
met
e
r list and er
ro
r
compensation table
P34.1 DP PLACES =
4
X1: Decimal places: 4 is the default setting
P34.2 DP PLACES =
4
X2: Decimal places: 4 is the default setting
P35.1 REF ON/OFF =
1
X1: Reference mark: 0 = off, 1 = on
P35.2 REF ON/OFF =
1
X2: Reference mark: 0 = off, 1 = on
P36.1 REF MARK =
5
X1: 0 = single reference mark, 1..6: coded reference marks
P36.2 REF MARK =
5
X2: 0 = single reference mark, 1..6: coded reference marks
P37.1
ALARM =
3
X1: 0 = off, 1 = frequency, 2 = contamination, 3 = frequency and
contamination
P37.2
ALARM =
3
X2: 0 = off, 1 = frequency, 2 = contamination, 3 = frequency and
contamination
P38
EXT. REF =
1
External REF input: 0 = inactive, 1 = active
P39.1 SCREW.PITCH =
88.123456
X1: Screw pitch in mm (multiturn rotary enc.), 10 mm is the default setting
P39.2 SCREW.PITCH =
10
X2: Screw pitch in mm (multiturn rotary enc.), 10 mm is the default setting
P40.1 ENC. COMP. =
2
X1: Axis error compensation: 0 = off, 1 = linear, 2 = non-linear
P40.2 ENC. COMP. =
2
X2: Axis error compensation: 0 = off, 1 = linear, 2 = non-linear
P41.1 LIN. COMP. =
+
0.0
X1: Linear compensation: 0.0 µm/m (default setting)
P41.2 LIN. COMP. =
+
0.0
X2: Linear compensation: 0.0 µm/m (default setting)
P43 .1 ANALOG U1 = +
10.000
X1: Analog module: Voltage 1 = 10.000 V (default setting)
P43 .2 ANALOG U1 = +
10.000
X2: Analog module: Voltage 1 = 10.000 V (default setting)
P44.1 ANALOG U2 = -
10.000
X1: Analog module: Voltage 2 = –10.000 V (default setting)
P44.2 ANALOG U2 = -
10.000
X2: Analog module: Voltage 2 = –10.000 V (default setting)
P45.1 ANALOG.POS1 = +
10.0000
X1: Analog module: Position 1 (10.000 is the default setting)
P45.2 ANALOG.POS1 = +
10.0000
X2: Analog module: Position 1 (10.000 is the default setting)
P46.1 ANALOG.POS2 = -
10.0000
X1: Analog module: Position 2 (–10.000 is the default setting)
P46.2 ANALOG.POS2 = -
10.0000
X2: Analog module: Position 2 (–10.000 is the default setting)
P47 ANALOG FCT = +
9.4
Temperature compensation: Coefficient +9.4 µ/K (default setting)
P48
REF. TEMP. = +
20.00
Temperature compensation: Reference temperature +20.0 ° (default
setting)
P49 ANALOG.COMP. =
1
Temperature compensation: 0 = off, 1 = on
P50
RS232/USB =
1
Interface: 0 = RS232, 1= USB
P51 BAUD RATE =
11
Baud rate = 115200 (0 - 11), 7 is the default setting
Parameter