Ii – 5 d a ta int e rf ace – HEIDENHAIN ND 287 User Manual User Manual
Page 110

110
II Installation, specifications
II – 5 D
a
ta int
e
rf
ace
Output of status bar:
0
3
0
1
0
0
1
2
16
a
b
c
d
e
f
g
h
17
16
STX control character: 1 character
a-h
Parameter values of the status bar: 8 characters
17
End of line: 2 characters
Column
Parameter
a
Operating mode
0 = Actual Value
1 = Distance-
To-Go
b
Display mode for
axis and coupled
axes
0 = X1
1 = X2
2 = X1 + X2
3 = X1 - X2
4 = f(X1, X2)
c
Scaling factor
0 = Not active
1 = Active
d
Compensation
0 = No
compensation
1 = Error compensation or axis-error compensation is active
e
Stopwatch
0 = Stopped
1 = Stopwatch is running
f
Unit of measure
0 = mm
1 = Inches
2 = DEG
3 = DMS
4 = rad
g
Datum
1 = Datum 1
2 = Datum 2
h
Soft-key page
1 = Page 1
2 = Page 2
3 = Page 3
4 = Keyboard is locked
This manual is related to the following products: