HEIDENHAIN ND 287 User Manual User Manual
Page 119

ND 287
119
II – 7 Input and output of par
a
met
e
r list and er
ro
r
compensation table
P39
SCREW.PITCH =
88.123456
Screw pitch in mm (multiturn rotary enc.), 10 mm is the default setting
P40 ENC. COMP. =
2
Axis error compensation: 0 = off, 1 = linear, 2 = non-linear
P41
LIN. COMP. =
+
0.0
Linear compensation: 0.0 µm/m (default setting)
P43 ANALOG U1 = +
10.000
Analog module: Voltage 1 = 10.000 V (default setting)
P44 ANALOG U2 =
-
10.000
Analog module: Voltage 2 = –10.000 V (default setting)
P45 ANALOG.POS1 = +
10.0000
Analog module: Position 1 (10.000 is the default setting)
P46 ANALOG.POS2 = -
10.0000
Analog module: Position 2 (–10.000 is the default setting)
P47 ANALOG FCT = +
9.4
Temperature compensation: Coefficient +9.4 µm/m·K (default setting)
P48
REF. TEMP. = +
20.00
Temperature compensation: Reference temperature +20 °C (default setting)
P49 ANALOG.COMP. =
1
Temperature compensation: 0 = off, 1 = on
P50
RS232/USB =
1
Interface: 0 = RS232, 1= USB
P51 BAUD RATE =
11
Baud rate = 115200 (0 - 11), 7 is the default setting
P52
DATA BIT =
0
Data bits: 0 = 7 bits , 1 = 8 bits
P53
STOP BIT =
0
Stop bit: 0 = 2 stop bits, 1 = 1 stop bit
P54
PARITY BIT =
1
Parity bit: 0 = none, 1 = even, 2 = odd
P55
BLANK LINE =
1
Blank lines: 1 (0 - 99)
P56 DISP.FREEZE =
0
Display freeze: 0 = current, 1 = frozen, 2 = stopped
P60
PRESET = +
0.0000
Value for preset via external signal: 0.0000
P61
A1 ON/OFF =
1
Switching output A1: 0 = off, 1 = on
P62
A2 ON/OFF =
1
Switching output A2: 0 = off, 1 = on
P63
LIMIT A1 = +
0.0000
Value for switching output A1: 0.0000
P64
LIMIT A2 = +
0.0000
Value for switching output A2: 0.0000
P66
PART NO. =
0
Part number selected: 0 is the default setting
P67
LOW.LIMIT 0 =
+
50.0000
LOW.LIMIT 1 =
+
0.0000
LOW.LIMIT 2 =
–
0.0170
LOW.LIMIT 3 =
–
25.0000
LOW.LIMIT 4 =
–
5.0000
LOW.LIMIT 5 =
–
6.0000
LOW.LIMIT 6 =
–
7.0000
LOW.LIMIT 7 =
–
7.0000
LOW.LIMIT 8 =
–
9.0000
LOW.LIMIT 9 =
–
254.0000
Lower tolerance limit for part 0 – part 9: 0.0000 is the default setting
Parameter
Meaning