Nd 287 with rotary encoder connected to input x1 – HEIDENHAIN ND 287 User Manual User Manual
Page 135

ND 287
135
II – 7 Input and output of par
a
met
e
r list and er
ro
r
compensation table
ND 287 with rotary encoder connected to input X1
The compensation points have a fixed spacing of two degrees relative
to each other.
Parameter
Meaning
#
Start character (#)
ND-287 1 DEG
Model: ND-287, Unit of measure: DEG, DMS or rad
AXIS X1
=
0
Axis to be compensated
COMP.NO. 000
= +
0.0000
=
+0.0000
Compensation value 0 = 0.0000 mm
(Compensation value 0 is always 0.0000 mm.)
COMP.NO. 001
= +
2.0000
=
...
Compensation value 1 = No value entered
COMP.NO. 002
= +
4.0000
=
...
Compensation values 2 - 179 = No values entered
Axis will not be compensated
.
COMP.NO. 003
= +
6.0000
=
...
COMP.NO. 004
= +
8.0000
=
...
COMP.NO. 005
= + 10.0000
=
...
COMP.NO. 006
= + 12.0000
=
...
COMP.NO. 007
= + 14.0000
=
...
COMP.NO. 008
= + 16.0000
=
...
COMP.NO. 009
= + 18.0000
=
...
COMP.NO. 010
= + 20.0000
=
...
COMP.NO. 011
= + 22.0000
=
...
COMP.NO. 012
= + 24.0000
=
...
COMP.NO. 013
= + 26.0000
=
...
COMP.NO. 014
= + 28.0000
=
...
COMP.NO. 015
= + 30.0000
=
...
COMP.NO. 016
= + 32.0000
=
...
COMP.NO. 017
= + 34.0000
=
...
COMP.NO. 018
= + 36.0000
=
...
...
COMP.NO. 173
= + 346.0000
=
...
COMP.NO. 174
= + 348.0000
=
...
COMP.NO. 175
= + 350.0000
=
...