Configuring qos on the gige switch – Grass Valley K2 Summit Storage Area Network Installation User Manual
Page 73

20. Click the
VLAN Configuration
tab.
21. If you have a trunk, verify that for the default VLAN the trunk is displayed in the Tagged Ports
column.
22. If you have two switches, repeat this procedure for the other switch.
23. Close the switch configuration application.
Next, configure QOS on the GigE switch.
Configuring QOS on the GigE switch
Prerequisites for this procedure are as follows:
•
The switch is HP ProCurve switch 29xx series.
•
Trunks, VLANs and all other configuration is complete.
•
The switch has an IP address
•
You have network access to the switch
Use this procedure to make the Quality of Service (QOS) setting on the HP ProCurve switch 29xx
series.
1. If you have not already done so, from a network connected PC open the MS-DOS command
prompt and login to the switch as administrator, as follows:
a) Telnet to the switch. For example, if the switch’s IP address is 192.168.40.12, you type the
following, then press
Enter
.
telnet 192.168.40.12
b) Press
Enter
one or more times until the switch’s username prompt appears.
c) Type the switch’s administrator username and press
Enter
, then type the switch’s administrator
password and press
Enter
. The switch console command (CLI) prompt appears.
18 November 2010
K2 SAN Installation and Service Manual
73
Setting up the K2 SAN infrastructure