beautypg.com

Configuring qos on the gige switch – Grass Valley K2 Summit Storage Area Network Installation User Manual

Page 73

background image

20. Click the

VLAN Configuration

tab.

21. If you have a trunk, verify that for the default VLAN the trunk is displayed in the Tagged Ports

column.

22. If you have two switches, repeat this procedure for the other switch.

23. Close the switch configuration application.

Next, configure QOS on the GigE switch.

Configuring QOS on the GigE switch

Prerequisites for this procedure are as follows:

The switch is HP ProCurve switch 29xx series.

Trunks, VLANs and all other configuration is complete.

The switch has an IP address

You have network access to the switch

Use this procedure to make the Quality of Service (QOS) setting on the HP ProCurve switch 29xx
series.

1. If you have not already done so, from a network connected PC open the MS-DOS command

prompt and login to the switch as administrator, as follows:

a) Telnet to the switch. For example, if the switch’s IP address is 192.168.40.12, you type the

following, then press

Enter

.

telnet 192.168.40.12

b) Press

Enter

one or more times until the switch’s username prompt appears.

c) Type the switch’s administrator username and press

Enter

, then type the switch’s administrator

password and press

Enter

. The switch console command (CLI) prompt appears.

18 November 2010

K2 SAN Installation and Service Manual

73

Setting up the K2 SAN infrastructure