To import/transcode files into the K2 system, do one of the following:

If you import SD only, place the SD files in the

SourceFiles

folder.

If you import HD only, place the HD files in the

SourceFiles

folder.

If you import both SD and HD, place SD files in the

SourceFiles

folder and place HD files

in the

HDSourceFiles

folder.

Open Carbon Admin and on the Active Jobs tab, monitor transcode/import progress. Then find
the K2 clip in the bin configured as the Import Watch Folder K2 bin.

To export/transcode clips out of the K2 system, in AppCenter place the clips in the bin configured
as the Export Watch Folder K2 bin. Open Carbon Admin and on the Active Jobs tab, monitor
progress. Then access the exported files in the

DestFiles

folder.

Only clips new to the bin are exported/transcoded. If there are clips in the Export Watch Folder
K2 bin that were present prior to configuring the bin as the Export Watch Folder, those clips are
not exported/transcoded.

Creating K2 Coder watch folders

The K2 Coder comes from Grass Valley pre-configured with watch folders. If you need to re-create
these watch folders, use the topics in this section.

Creating the import watch folder

1. Run Carbon Coder Admin.

2. Select the

Watch Folders

tab.

3. Click the

Add Watch

button.

4. Select

General Properties

on the left pane.

5. Enter

ImportWatchFolderTemplate

as the name for the watch folder.

The name is for display purposes only.

6. To set the Watch Folder location, select

Browse Folders

to

V:\K2Coder\SourceFiles

.

7. Select

Create New File

if target file exists.

8. Under

Advanced Settings

, select

Delete Local Source after Conversion

.

9. In the left pane expand

Remote Retrieve

, then

File Retrieve

, then under

File Retrieve

click

Add...

.

10. Select

Remote Patch (UNC)

. Browse and go to

V:\K2Coder\ShortCuts

and

OK

.

11. Select

Create Shortcut instead of Local Copy

.

12. In Retrieval Settings set Wildcard to

"*"

, Watch Interval (sec.) to

10

, Trigger File Size (kB) to

0

.

13. Click the

Update

button.

14. Expand

Target File

on the left pane, then click

Add...

.

15. On the right pane Preset Category, select

System

, then select a preset such as

K2_SD_NTSC_IFRAME_50Mbps_Template from the list.

16. Click on the

Preset Editor

page.

17. Set the Target Folder to

V:\K2Coder\FilesToK2

.

18. Click the

Update

button.

350

K2 SAN Installation and Service Manual

18 November 2010

Working with the K2 Coder