Binding disk modules - basic k2 san – Grass Valley K2 Summit Storage Area Network Installation User Manual
Page 138

6. For SNMP Configuration, enter the IP address of the NetCentral server PC.
You can also enter IP addresses for other SNMP managers to which you want to send SNMP
trap messages.
7. Click
OK
to save settings and close.
8. In Storage Utility click
View | Refresh
.
Next, bind disk modules.
Binding disk modules - Basic K2 SAN
Prerequisites for the K2 RAID chassis are as follows:
•
Fibre Channel cable(s) connected
•
Ethernet cable(s) connected
•
Power on
Prerequisites for the optional K2 RAID Expansion chassis (if present) are as follows:
•
Fibre channel cable(s) connected
•
Power on
NOTE: Binding destroys all user data on the disks.
1. If you have not already done so, launch Storage Utility from the K2Config application.
2. As prompted, wait while Storage Utility gathers system information, then Storage Utility opens.
3. In the Storage Utility main window, identify bound RANKs and unbound disks by their placement
in the hierarchy of the tree view. In the following illustration, disk numbers are represented by
“XX”.
138
K2 SAN Installation and Service Manual
18 November 2010
Configuring and licensing the K2 SAN