6. For SNMP Configuration, enter the IP address of the NetCentral server PC.

You can also enter IP addresses for other SNMP managers to which you want to send SNMP
trap messages.

7. Click

OK

to save settings and close.

8. In Storage Utility click

View | Refresh

.

Next, bind disk modules.

Binding disk modules - Basic K2 SAN

Prerequisites for the K2 RAID chassis are as follows:

Fibre Channel cable(s) connected

Ethernet cable(s) connected

Power on

Prerequisites for the optional K2 RAID Expansion chassis (if present) are as follows:

Fibre channel cable(s) connected

Power on

NOTE: Binding destroys all user data on the disks.

1. If you have not already done so, launch Storage Utility from the K2Config application.

2. As prompted, wait while Storage Utility gathers system information, then Storage Utility opens.

3. In the Storage Utility main window, identify bound RANKs and unbound disks by their placement

in the hierarchy of the tree view. In the following illustration, disk numbers are represented by
“XX”.

138

K2 SAN Installation and Service Manual

18 November 2010

Configuring and licensing the K2 SAN