6. Wait until the CLI prompt re-appears, then continue with the next step in this procedure.

7. Check the version of firmware on the switch. To do this, type the following, then press

Enter

:

show flash

Information is displayed similar to the following example:

HP_iSCSI_switch1# show flash
Image Size(Bytes) Date Version
----- ---------- -------- -------
Primary Image : 6737518 07/25/08 T.13.23
Secondary Image : 5886358 10/26/06 T.11.12
Boot Rom Version: K.12.12
Current Boot : Primary

8. Verify that the new software version is in the expected flash area (primary or secondary).

9. Restart the switch from the flash area that holds the new software (primary or secondary).