beautypg.com

Grass Valley K2 Summit Storage Area Network Installation User Manual

Page 197

background image

Prerequisites for the optional K2 RAID Expansion chassis (if present) are as follows:

Fibre channel cable(s) connected

Power on

Use the Storage Utility to configure the following settings for the K2 RAID controller:

IP address

Subnet mask

Gateway Address

SNMP trap destinations

For K2 RAID, network and SNMP settings are set and stored on the RAID controller module, so
the combined RAID storage devices, including the optional Expansion chassis, exist as a single
entity on the control network.

The RAID storage device is configured by default for the SNMP community name “public”. If your
site’s policies require using a different SNMP community name, contact your Grass Valley
representative.

1. Launch Storage Utility from the K2Config application.

2. As prompted, wait while Storage Utility gathers system information, then Storage Utility opens.

3. In Storage Utility tree view, expand the node for the K2 RAID, right-click the icon for a RAID

controller, and select

Configuration | Network Properties

.

The Controller Network Settings dialog box opens.

18 November 2010

K2 SAN Installation and Service Manual

197

Configuring and licensing the K2 SAN