Use the Storage Utility to configure the following settings for the K2 RAID controller:
•
IP address
•
Subnet mask
•
Gateway Address
•
SNMP trap destinations
For K2 RAID, network and SNMP settings are set and stored on the RAID controller module, so
the combined RAID storage devices, including the optional Expansion chassis, exist as a single
entity on the control network.
The RAID storage device is configured by default for the SNMP community name “public”. If your
site’s policies require using a different SNMP community name, contact your Grass Valley
representative.
1. Launch Storage Utility from the K2Config application.
2. As prompted, wait while Storage Utility gathers system information, then Storage Utility opens.
3. In Storage Utility tree view, expand the node for the K2 RAID, right-click the icon for a RAID
controller, and select
Configuration | Network Properties
.
The Controller Network Settings dialog box opens.
4. In the Controller Slot Number field enter
0
and then press
Enter
.
The settings from controller 0 are loaded into the Controller Network Settings dialog box and
are available for you to modify.
5. Enter the control network IP address and other network settings.