Dell r610 nh10ge for redundant nearline k2 san, Cable k2 raid, K2 raid for basic k2 san – Grass Valley K2 Summit Storage Area Network Installation User Manual
Page 58

Dell R610 NH10GE for redundant nearline K2 SAN
These cabling instructions apply to the following:
•
Dell R610 PowerEdge Server NH10GE on a nearline K2 SAN.
Cable K2 RAID
Before cabling, install the K2 RAID chassis in its permanent location. After mounting the chassis
in the rack, you must secure brackets to the front rail to support the Grass Valley bezel. Refer to the
K2 10G RAID Instruction Manual for rack mount instructions.
On the 10G RAID, you do not need to manually set a Fibre Channel address ID on controllers or a
chassis address on Expansion chassis.
As directed by the system diagram for your K2 storage, cable the K2 RAID devices using the
instructions in this section.
Once the RAID storage is connected and configured, do not swap Expansion chassis or otherwise
reconfigure storage. If you connect an Expansion chassis in a different order or to the wrong
controller, the controller will see a configuration mismatch and fault.
Related Links
on page 58
on page 59
K2 RAID for basic nearline K2 SAN
on page 60
K2 RAID for redundant nearline K2 SAN
on page 61
K2 RAID for basic K2 SAN
These cabling instructions apply to the following:
•
K2 RAID (Condor with 10G controller) on a basic (non-redundant) online or production K2
SAN.
58
K2 SAN Installation and Service Manual
18 November 2010
Cabling K2 SAN devices