beautypg.com

Grass Valley K2 Summit Storage Area Network Installation User Manual

Page 161

background image

3. In Storage Utility tree view, expand the node for the K2 RAID, right-click the icon for a RAID

controller, and select

Configuration | Network Properties

.

The Controller Network Settings dialog box opens.

4. In the Controller Slot Number field enter

0

and then press

Enter

.

The settings from controller 0 are loaded into the Controller Network Settings dialog box and
are available for you to modify.

5. Enter the control network IP address and other network settings.

6. For SNMP Configuration, enter the IP address of the NetCentral server PC.

You can also enter IP addresses for other SNMP managers to which you want to send SNMP
trap messages.

7. For the RAID chassis with two controllers, in the Controller Slot Number field enter

1

and then

press

Enter

.

The settings from controller 1 are loaded into the Controller Network Settings dialog box and
are available for you to modify.

8. Repeat the previous steps to configure controller 1.

9. Click

OK

to save settings and close.

10. In Storage Utility click

View | Refresh

.

Next, bind disk modules.

18 November 2010

K2 SAN Installation and Service Manual

161

Configuring and licensing the K2 SAN