Grass Valley K2 Summit Storage Area Network Installation User Manual
Page 66

23. Enter the SNMP community and IP address of the NetCentral server PC. The commands are
slightly different on HP 2900 and HP 2910 switch models.
For example, if the IP address is “192.168.40.11” and the community is “public”, you type one
of the following as per your switch model, then press Enter:
HP 2900:
snmp-server host public 192.168.40.11
HP 2910:
snmp-server host 192.168.40.11 public
24. Enable Authentication traps. To do this, type the following, then press
Enter
:
snmp-server enable traps snmp-authentication standard
This allows NetCentral to test the switch to verify that it can send its SNMP trap messages to
NetCentral.
25. Type the following, then press
Enter
:
menu
When prompted, save the configuration by pressing the y key.
The main menu opens.
26. If you need a trunk for ISLs to gang switches together, use the following steps. These steps
illustrate trunking the last three 1 Gig ports for three 1 Gig ISLs, which is the recommended
configuration for ISLs on all multi-switch K2 SANs. Consult with your Grass Valley representative
if your requirements deviate from the recommended policy:
a) At the main menu, select
Switch Configuration
and press
Enter
.
b) Choose selection
Port/Trunk Settings
and press
Enter
.
c) Press the right-arrow key to choose
Edit
, then press
Enter
.
d) Down arrow until at the bottom of the list of ports and select the last (highest port number)
1 Gig port in the list.
e) Right-arrow over to the Group column.
f) Use the Space bar and set the bottom 1 Gig port to
Trk1
.
g) Set the next port up also to
Trk1
.
h) Set the next port up also to
Trk1
.
i) Press
Enter
, then right-arrow to
Save
. Press
Enter
and revert to previous menu.
27. Select
Return to Main Menu
and press
Enter
.
28. From the main menu, tab to
Command Line (CLI)
and press
Enter
. The command prompt appears.
29. Check the version of firmware on the switch. To do this, type the following, then press
Enter
:
show flash
Information is displayed similar to the following example:
HP_iSCSI_switch1# show flash
Image Size(Bytes) Date Version
----- ---------- -------- -------
Primary Image : 6737518 07/25/08 T.13.23
Secondary Image : 5886358 10/26/06 T.11.12
Boot Rom Version: K.12.12
Current Boot : Primary
66
K2 SAN Installation and Service Manual
18 November 2010
Setting up the K2 SAN infrastructure