23. Enter the SNMP community and IP address of the NetCentral server PC. The commands are

slightly different on HP 2900 and HP 2910 switch models.

For example, if the IP address is “192.168.40.11” and the community is “public”, you type one
of the following as per your switch model, then press Enter:

HP 2900:

snmp-server host public 192.168.40.11

HP 2910:

snmp-server host 192.168.40.11 public

24. Enable Authentication traps. To do this, type the following, then press

Enter

:

snmp-server enable traps snmp-authentication standard

This allows NetCentral to test the switch to verify that it can send its SNMP trap messages to
NetCentral.

25. Type the following, then press

Enter

:

menu

When prompted, save the configuration by pressing the y key.

The main menu opens.

26. If you need a trunk for ISLs to gang switches together, use the following steps. These steps

illustrate trunking the last three 1 Gig ports for three 1 Gig ISLs, which is the recommended
configuration for ISLs on all multi-switch K2 SANs. Consult with your Grass Valley representative
if your requirements deviate from the recommended policy:

a) At the main menu, select

Switch Configuration

and press

Enter

.

b) Choose selection

Port/Trunk Settings

and press

Enter

.

c) Press the right-arrow key to choose

Edit

, then press

Enter

.

d) Down arrow until at the bottom of the list of ports and select the last (highest port number)

1 Gig port in the list.

e) Right-arrow over to the Group column.
f) Use the Space bar and set the bottom 1 Gig port to

Trk1

.

g) Set the next port up also to

Trk1

.

h) Set the next port up also to

Trk1

.

i) Press

Enter

, then right-arrow to

Save

. Press

Enter

and revert to previous menu.

27. Select

Return to Main Menu

and press

Enter

.

28. From the main menu, tab to

Command Line (CLI)

and press

Enter

. The command prompt appears.

29. Check the version of firmware on the switch. To do this, type the following, then press

Enter

:

show flash

Information is displayed similar to the following example:

HP_iSCSI_switch1# show flash
Image Size(Bytes) Date Version
----- ---------- -------- -------
Primary Image : 6737518 07/25/08 T.13.23
Secondary Image : 5886358 10/26/06 T.11.12
Boot Rom Version: K.12.12
Current Boot : Primary