background image

4. Right-click the

Unbound

node for a controller, then select

Bind

in the context menu.

If the RAID chassis has two controllers, both controllers are represented by the single “Controller”
node.

The Bind dialog box opens showing all unbound disks for the controller listed in the Available
Disk list.

5. Leave

Full Bind

unchecked.

6. In the

Bind Type

drop down box, select

RAID 5

or

RAID 6

, as specified by your system design.

7. In the Available Disks box, select six contiguous disks at the top of the list.

Use ‘shift-click’ or ‘control-click’ to select disks.

8. Click the add (arrow) button to add disks to the Selected Disks list.

NOTE: As an aid in identifying a disk module’s physical location, select it in the Selected
Disks list, then click Identify Disks. This causes the disk drive light to flash.