Control Team failover behavior

If the following system connection or component fails to respond to network communication:

The control connection between a K2 client and GigE switch “A”.

Then the following failover behavior occurs:

1. The control team on the K2 client fails over and communication begins on the other control port.
2. The control communication finds a path through GigE “B” switch and across an ISL to GigE

switch “A” to reach the same control port on the same K2 Media Server.

3. Media (iSCSI) traffic keeps using the same path.
4. K2 Media Server “A” is still the media file system/metadata server. The media file system (SNFS)

and media database do not fail over.

5. The other K2 clients (not affected by the connection failure) keep using the same paths for media

and control, as in pre-failover behavior.

254

K2 SAN Installation and Service Manual

18 November 2010

Operating the K2 SAN