beautypg.com

Downloading disk drive firmware – Grass Valley K2 Summit Storage Area Network Installation User Manual

Page 324

background image

2. In Storage Utility, right-click a controller in the tree view, then do one of the following:

To load controller microcode select

Advanced | Load Controller Microcode

To load expansion chassis microcode select

Advanced | Load Disk Enclosure Microcode

Redundant controllers that share the same set of disks are automatically selected and upgraded
as a pair.

The Open File dialog box appears.

3. In the Open File dialog box, browse to the latest controller microcode file, select the file, and

click

OK

.

4. The Progress Report window appears showing the microcode upgrade task and the percentage

completion.

5. On 100% completion, proceed as follows:

If the RAID controller chassis has redundant controllers, no power cycle is required. The
firmware download is complete.

If the RAID controller chassis does not have redundant controllers, power cycle the RAID
controller chassis, then restart the K2 Media Server.

Downloading disk drive firmware

Prerequisites are as follows:

All K2 clients and other clients must be powered down, or in some other way disconnected from
the K2 SAN.

The K2 Media Server through which Storage Utility is connected to the RAID Storage must be
powered up.

All other K2 Media Servers must be powered down.

324

K2 SAN Installation and Service Manual

18 November 2010

Administering and maintaining the K2 SAN