beautypg.com

Grass Valley K2 Summit Storage Area Network Installation User Manual

Page 200

background image

4. Right-click the

Unbound

node for a controller, then select

Bind

in the context menu.

If the RAID chassis has two controllers, both controllers are represented by the single “Controller”
node.

The Bind dialog box opens showing all unbound disks for the controller listed in the Available
Disk list.

5. Leave

Full Bind

unchecked.

6. In the

Bind Type

drop down box, select

RAID 6

.

7. In the Available Disks box, select twelve contiguous disks at the top of the list.

Use ‘shift-click’ or ‘control-click’ to select disks.

8. Click the add (arrow) button to add disks to the Selected Disks list.

NOTE: As an aid in identifying a disk module’s physical location, select it in the Selected
Disks list, then click Identify Disks. This causes the disk drive light to flash.

200

K2 SAN Installation and Service Manual

18 November 2010

Configuring and licensing the K2 SAN