beautypg.com

Power off k2 raid, Power off remaining k2 san devices, Powering on the k2 san – Grass Valley K2 Summit Storage Area Network Installation User Manual

Page 245

background image

3. Shut down any remaining K2 Media Servers, such as NH FTP servers.

Next, power off K2 RAID devices.

Power off K2 RAID

Prerequisites for this task are as follows:

K2 Media Servers are powered off

1. On the primary RAID chassis controller, identify the RDY LED. It blinks at a rate of 1 blink per

second during normal operation.

Power Cords

(115V/230V)

RDY

LED

RDY

LED

Power Good

LED

Power Good

LED

2. Press and hold down the power button on a RAID controller. If you have two controllers, you

can press the power button on either RAID controller 0 or RAID controller 1.

3. Release the power button in about 5 seconds, when the RDY LED blinks more quickly, at a rate

of about 2 blinks per second. Do not hold down the power button for longer than 15 seconds.

The power button on the RAID controller turns off power for the primary RAID chassis and any
connected Expansion chassis. Power-off normally occurs within 20 seconds and is indicated
when LEDs other than those on the power supplies go off and the fans stop rotating.

4. Wait for RAID power-off to complete before proceeding.

5. Power-off all Ethernet switches.

6. Power-off the control point PC and/or the NetCentral server PC, if necessary.

Next, power off remaining SAN devices.

Power off remaining K2 SAN devices

1. Power-off all Ethernet switches.

2. Power-off the control point PC and/or the NetCentral server PC, if necessary.

The K2 SAN is powered off.

Powering on the K2 SAN

Use the following procedures to do an orderly power on of the complete K2 SAN.

Related Links

Basic K2 SAN power on procedure

on page 246

Redundant K2 SAN power on procedure

on page 247

18 November 2010

K2 SAN Installation and Service Manual

245

Operating the K2 SAN