beautypg.com

Dell r610 gs for basic k2 san, Dell r610 gs for redundant k2 san, Serial cable specifications – Grass Valley K2 Summit Storage Area Network Installation User Manual

Page 56

background image

Dell R610 GS for redundant K2 SAN

on page 56

Dell R610 GS for basic K2 SAN

These cabling instructions apply to the following:

Dell R610 PowerEdge Server on a basic (non-redundant) online or production K2 SAN.

Dell R610 GS for redundant K2 SAN

These cabling instructions apply to the following:

Dell 1950 PowerEdge Server on a redundant online or production K2 SAN.

Serial cable specifications

Take care to use the proper serial cable to interconnect redundant K2 Media Servers that take the
role of file system/database servers. This cable supports the heartbeat mechanism whereby the
servers monitor each other’s health. It is a 9 pin serial cable, but it is not a standard RS-232 null
modem cable. The heartbeat cable is supplied with your system (Grass Valley part number
174-8137-00) and has a pin configuration as follows:

1 – 4

2 – 3

3 – 2

4 – 1&6

56

K2 SAN Installation and Service Manual

18 November 2010

Cabling K2 SAN devices