beautypg.com

Raid drive numbering – Grass Valley K2 System Guide v.7.2 User Manual

Page 31

background image

07 April 2010

K2 System Guide

31

RAID drive numbering

RAID drive numbering

In the K2 Summit Production Client, internal RAID drives are numbered as follows.
This numbering is displayed in Storage Utility. You cannot see the labeling on the K2
Summit Production Client chassis RAID drive when you remove the fan module.

In the K2 Solo Media Server, internal RAID drives are numbered as follows:

NOTE: K2 Solo Media Server drives are always configured as RAID 0.

When drives are configured as RAID 0, each drive is considered its own LUN. As
such, the order of LUNs and drive numbers as displayed in Storage Utility does not
always correlate with the position of drives in the chassis.

Disk2

Disk4

Disk7

Disk1

Disk3

Disk6

Disk0

Disk5

Drive numbering

Explanation

Disk0

When configured as RAID 1, these two RAID drives make up LUN 0.

Disk1

Disk2

When configured as RAID 1, these two RAID drives make up LUN 1.

Disk3

Disk4

When configured as RAID 1, these two RAID drives make up LUN 2.

Disk5

Disk6

When configured as RAID 1, these two RAID drives make up LUN 3.

Disk7

Disk0

Disk1

This manual is related to the following products: