Raid drive numbering – Grass Valley K2 System Guide v.7.2 User Manual
Page 31

07 April 2010
K2 System Guide
31
RAID drive numbering
RAID drive numbering
In the K2 Summit Production Client, internal RAID drives are numbered as follows.
This numbering is displayed in Storage Utility. You cannot see the labeling on the K2
Summit Production Client chassis RAID drive when you remove the fan module.
In the K2 Solo Media Server, internal RAID drives are numbered as follows:
NOTE: K2 Solo Media Server drives are always configured as RAID 0.
When drives are configured as RAID 0, each drive is considered its own LUN. As
such, the order of LUNs and drive numbers as displayed in Storage Utility does not
always correlate with the position of drives in the chassis.
Disk2
Disk4
Disk7
Disk1
Disk3
Disk6
Disk0
Disk5
Drive numbering
Explanation
Disk0
When configured as RAID 1, these two RAID drives make up LUN 0.
Disk1
Disk2
When configured as RAID 1, these two RAID drives make up LUN 1.
Disk3
Disk4
When configured as RAID 1, these two RAID drives make up LUN 2.
Disk5
Disk6
When configured as RAID 1, these two RAID drives make up LUN 3.
Disk7
Disk0
Disk1