Rack mounting, Rack-mount considerations, Appendix d – Grass Valley K2 System Guide v.7.2 User Manual
Page 241

07 April 2010
K2 System Guide
241
Appendix
D
Rack mounting
This section contains the following topics:
•
•
“Rack mount hardware shipped with the K2 system”
•
•
“Installing the K2 system on the rack mount rails”
•
“Making Rack Slide Adjustments”
Rack-mount considerations
When planning the placement of equipment in your equipment rack, bear in mind the
following:
• Ensure adequate air flow around the chassis to provide sufficient cooling.
Operating ambient temperature will affect the amount of air circulation required to
keep the K2 system within its temperature limitations. See
for details.
• If the system is installed with its ventilation intakes near another system's exhaust
or in a closed or multi-unit rack assembly, the operating ambient temperature
inside the chassis may be greater than the room's ambient temperature. Install the
system in an environment compatible with this recommended maximum ambient
temperature.
• Ensure the rack is anchored to the floor so that it cannot tip over when the K2
system is extended out of the rack.
• Be sure to mount the K2 system in a way that ensures even weight distribution in
the rack. Uneven mechanical loading can result in a hazardous condition. Secure
all mounting bolts when installing the chassis to the rack.
The following sections describe installing the K2 Summit Production Client
step-by-step. For the K2 Solo Media Server, refer to K2 Solo Media Server
Accessories Installation Instructions that you received with the rack kit.