Ac power specification, Environmental specifications – Grass Valley K2 System Guide v.7.2 User Manual
Page 190

190
K2 System Guide
07 April 2010
Appendix B Specifications
AC power specification
The K2 Summit Production Client specification is shown in the following table.
The K2 Solo Media Server specification is shown in the following table.
WARNING: Always use a grounded outlet to supply power to the
system. Always use a power cable with a grounded plug, such as the one
supplied with the system.
Environmental specifications
The K2 Summit Production Client and K2 Solo Media Server specification is shown
in the following table.
Characteristic
Specification
Power supply
Dual, redundant
Mains Input Voltage
90 to 260V auto-range, 47-63Hz
Power consumption
450W typical (standalone)
300W typical (SAN client)
Maximum AC current 4.5A @ 115VAC, 2.3A@230VAC
Characteristic
Specification
Power supply
Single
Mains Input Voltage
100-240V, 50/60 Hz
Power consumption
180W typical
Maximum AC current 4.5A @ 115VAC, 2.3A@230VAC
!
Characteristic
Specification
Ambient Temperature
Non-Operating
-40° to +60° C
Ambient Temperature
Operating
10° to +40° C
Relative Humidity
Operating 20% to 80% from -5 to +45 C
Non-Operating 10% to 80% from -30 to +60 C
Do not operate with visible moisture on the circuit boards
Operating Altitude
To 10,000 feet
IEC 950 compliant to 2000 meters
Storage Altitude
To 40,000 feet
Non-Operating
Mechanical Shock
30G 11 ms trapezoid