3 ground connector – Comtech EF Data CDM-600/600L User Manual
Page 72

CDM-600/600L Open Network Satellite Modem
Revision 3
Rear Panel Connector Pinouts
MN/CDM600L.IOM
3–12
CDM-600L CDM-600
LOCATION LOCATION
3.5.2 Direct Current (DC) Power Connector (Optional, CDM-600L only)
This optional connector supplies the Direct Current (DC) power to
the modem.
Note the following:
DC Power Specifications
Input Power
250W maximum, 55W typical without BUC power supply
Input Voltage
38-60 VDC
Connector Type
Molex 03-12-1026 with 08-12-1222 terminals
Fuse Protection
T3.15A Slow-blow 20mm fuses without internal BUC power supply
8.0A Slow-blow 20 mm fuses with internal BUC power supply
Positive and negative fusing
IMPORTANT
For continued operator safety, always replace the fuses with
the correct type and rating.
3.5.3 Ground Connector
A #10-32 stud is used for connecting a common chassis ground
among equipment. The stud location differs between the
CDM-600L and the CDM-600 chassis (see left).
Note: The AC power connector provides the safety ground.