1 config: remote ( local or remote settings – Comtech EF Data CDM-600/600L User Manual
Page 103

CDM-600/600L Open Network Satellite Modem
Revision 3
Front Panel Operation
MN/CDM600L.IOM
5–27
5.4.10.1
CONFIG: REMOTE
Æ LOCAL or REMOTE Settings
INTERFACE= RS-485-4W (232,485-2,485-4)
ADDRESS= 0001 BAUDRATE= 9600
For either Local control or Remote control, select the parameter to edit – Interface, Address, or
Baudrate – using the [
←][→] arrow keys, then edit the parameter as follows:
• To set the Interface type, select 232, 485-2 (2-Wire), or 484-4 (4-wire) using the [↑][↓]
arrow keys. Press [ENT] when done.
• To edit the Address, select the digit to be edited using the [←][→] arrow keys, then edit
the value of the digit using the [
↑][↓] arrow keys. Press [ENT] when done.
Note the following:
o For RS-485: The permitted address range is 1 to 9999. Address 0 is reserved for
universal addressing.
o For RS-232: The Address is fixed at 0000.
• Set the Baudrate using the [↑][↓] arrow keys, then press [ENT] when done.
CONFIG: REMOTE
Æ CHAR FORMAT
PARITY:DATA-BITS:STOP-BITS = N81
(N81,E72,O72)
Edit the I/O character format using the [
↑][↓] arrow keys. The options are:
• N81 – No parity, 8 data bits, 1 stop bit.
• E72 – Even parity, 7 data bits, 2 stop bits.
• O72 – Odd parity, 7 data bits, 2 stop bits.