beautypg.com

D.6.5 bulk commands – Comtech EF Data CDM-600/600L User Manual

Page 223

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix D

MN/CDM600L.IOM

D–31

D.6.5 Bulk Commands

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Drop & Insert

DNI=

51 bytes

Command or Query.
In the form ddddddddddddddddddddddddtiiiiiiiiiiiiiiiiiiiiiiiiTL, where:

25 bytes of Drop information:

d=24 bytes defining Timeslot locations
t=Drop Type: 0=T1-D4, 1=T1-ESF, 2=E1-CCS, 3=E1-CAS (same
as DTY)

25 bytes of Insert information:

i=24 bytes defining Timeslot locations
T=Insert Type: 0=T1-D4, 1=T1-ESF, 2=E1-CCS, 3=E1-CAS (same
as ITY)

1 byte for Drop and Insert Internal Loop:

L= 0 (OFF), 1 (ON)

D&I Timeslot locations definition:

0 = Unused channel
1-9 for timeslots 1–9, A=10, B=11, C=12, D=13 … V=31.

Example:
123456789ABC0000000000003123456789ABC00000000000031

where:

For both Drop & Insert: Channels 1–12 using timeslots 1–12, and
unused channels 13–24, E1-CAS type, Internal Loop ON.

If framing is D&I and data rate is 1920 kbps and DNI Type is E1-CCS
or E1-CAS, then channels cannot be programmed. The DNI? query
will display all ‘x’in the time-slot positions.

DNI=
DNI?
DNI*
DNI#

DNI?









DNI?n

DNI=ddddddddddddddddd
dddddddtiiiiiiiiiiiiiiiiiiiiiiiiTL
(see Description of
Arguments)

Returns current D&I
configuration



Where n=0 to 9 returns the
DNI portion of 1 of 10
stored configurations

(see Description of
Arguments)