J.3 front panel operation, Config: tx ( power, Config: tx ( power ( mode ( manual – Comtech EF Data CDM-600/600L User Manual
Page 273: Config: tx ( power ( mode ( manual-low

CDM-600/600L Open Network Satellite Modem
Revision 3
Appendix J
MN/CDM600L.IOM
J–3
J.3
Front Panel Operation
For complete information on modem operations via the CDM-600L front panel, refer to Chapter 5.
FRONT PANEL OPERATION.
Features associated with enhanced operation via the External 20 dB Step Attenuator Kit are shown
IN BOLD
. From the CDM-600L front panel:
CONFIG:
TX
Æ POWER
Without the External 20 dB Step Attenuator Kit installed, the CONFIG: TX Æ POWER menu
may appear as follows:
When the programmable External Attenuator is detected, the appearance of the menu display
updates accordingly:
Use the [
←][→] arrow keys to select the TX PWR MODE parameter (on the top line of the
display), then use the [
↑] [↓] arrow keys to select the Tx Power Mode. Selections may include:
Tx Power Mode
Description
MANUAL
This is the normal power mode, with a calibrated Tx power level range of
–40 to 0dBm. Level values of –45 to 0 dBm are permitted; values noted with
*
indicate when a level exceeds the specification. The External Attenuator
will be switched off, if present.
MANUAL-LOW
This is a manual power mode with the programmable External Attenuator
activated. The calibrated Tx power level range is -60 to -20 dBm. Level
values of -65 to -60 dBm are permitted; values noted with
*
indicate when
a level exceeds the specification.
AUPC
Available only if EDMAC or D&I++ is enabled. The External Attenuator will
be switched off, if present.
AUPC-LOW
This is the AUPC mode, available only if EDMAC or D&I++ is enabled, with
the External Attenuator activated.
CONFIG: TX
Æ POWER Æ MODE Æ MANUAL
CONFIG: TX
Æ POWER Æ MODE Æ MANUAL-LOW
For either of the Manual modes selected, select each digit of the LEVEL (Tx Power Level)
parameter (on the bottom line of the display) using the [
←][→] arrow keys, then edit the value of
the digit using the [
↑][↓] arrow keys.
Press [ENT] when done.
OUTPUT POWER: MODE= MANUAL(MANUAL,AUPC)
OUTPUT POWER LEVEL= –15.0 dBm
TX PWR MODE= MANUAL-LOW (MAN,AUPC(LOW))
OUTPUT POWER LEVEL= –35.0 dBm