F.3.5 (select:) monitor, F.3.5.1 monitor: lnb, F.3.5.2 monitor: buc – Comtech EF Data CDM-600/600L User Manual
Page 258

CDM-600/600L Open Network Satellite Modem
Revision 3
Appendix F
MN/CDM600L.IOM
F–8
F.3.5
(SELECT:) MONITOR
MONITOR: LIVE-ALARMS STORED-EVENTS
STATISTICS RX-PARAMS AUPC-PARAM LNB BUC
For ODU operation, select LNB or BUC using the [
←][→] arrow keys, then press [ENT].
F.3.5.1 MONITOR: LNB
LNB: CURRENT = xxx mA Voltage = xx V
The read-only Monitor: LNB screen displays the measured LNB current load and LNB voltage
at the Rx IF connector.
F.3.5.2 MONITOR: BUC
BUC:CURRENT =0000mA VOLT =47.9V CLASS =N/A
PWR =N/A Amb =N/A PLL =N/A VER =NA
The read-only Monitor: BUC screen displays the following operating parameters:
CURRENT
If a BUC supply is installed, displays the BUC supply load current,
measured at the Tx-IF connector.
VOLT
If a BUC supply is installed, displays the BUC supply voltage, measured at
the Tx-IF connector.
CLASS
If BUC FSK is enabled, displays the output power rating of the BUC.
PWR
If BUC FSK is enabled, displays the output power of the BUC, as measured
by the BUC power monitor.
AMB
If BUC FSK is enabled, displays BUC ambient temperature in
°C.
PLL
If BUC FSK is enabled, displays the fault status of the BUC PLL
synthesizers.
VER
If BUC FSK is enabled, displays the M&C software version of the BUC.