F.3.5 (select:) monitor, F.3.5.1 monitor: lnb, F.3.5.2 monitor: buc – Comtech EF Data CDM-600/600L User Manual

Page 258

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix F

MN/CDM600L.IOM

F–8

F.3.5

(SELECT:) MONITOR

MONITOR: LIVE-ALARMS STORED-EVENTS
STATISTICS RX-PARAMS AUPC-PARAM LNB BUC

For ODU operation, select LNB or BUC using the [

][] arrow keys, then press [ENT].

F.3.5.1 MONITOR: LNB

LNB: CURRENT = xxx mA Voltage = xx V

The read-only Monitor: LNB screen displays the measured LNB current load and LNB voltage
at the Rx IF connector.

F.3.5.2 MONITOR: BUC

BUC:CURRENT =0000mA VOLT =47.9V CLASS =N/A
PWR =N/A Amb =N/A PLL =N/A VER =NA

The read-only Monitor: BUC screen displays the following operating parameters:

CURRENT

If a BUC supply is installed, displays the BUC supply load current,
measured at the Tx-IF connector.

VOLT

If a BUC supply is installed, displays the BUC supply voltage, measured at
the Tx-IF connector.

CLASS

If BUC FSK is enabled, displays the output power rating of the BUC.

PWR

If BUC FSK is enabled, displays the output power of the BUC, as measured
by the BUC power monitor.

AMB

If BUC FSK is enabled, displays BUC ambient temperature in

°C.

PLL

If BUC FSK is enabled, displays the fault status of the BUC PLL
synthesizers.

VER

If BUC FSK is enabled, displays the M&C software version of the BUC.