beautypg.com

Comtech EF Data CDM-600/600L User Manual

Page 209

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix D

MN/CDM600L.IOM

D–17

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx Eb/No

N/A

4 bytes

Query only.
Unit returns the value of Eb/No, between 0 to 16 dB.
Resolution 0.1 dB.

Returns 99.9 if demod is unlocked.
Returns +016 for values greater than 16.0 dB.

Example: EBN=12.3 (Eb/No = 12.3 dB)

N/A EBN?

EBN=xxxx
(see Description of
Arguments)

Invert Rx
Data

IRD=

1 byte, value 0
or 1

Command or Query.
Invert Rx Data, where:
0=Normal
1=Inverted

Example: IRD = 1 (selects Inverted RX Data)

IRD=
IRD?
IRD*
IRD#

IRD? IRD=x

(see Description of
Arguments)

Insert
Timeslot

ITS=

3 bytes

Command or Query.
(Insert mode parameter)

(Note: Command and query have different formats)

Command is in the form xy, where:

xx = Channel 01 through 24
y = timeslot: 0-9, A=10, B=11, C=12, D=13 … V=31

ITS=
ITS?
ITS*
ITS#

ITS? ITS=yyyyyyyyyyyyyyyyyy

yyyyyy
indicating all 24 Insert
timeslot values
associated with the 24 Rx
Satellite channels.

Insert Type

ITY=

1 byte, value of
0 thru 3

Command or Query.
(Insert/D&I++ parameter)
Insert Type, where:
0=T1 – D4
1=T1 – ESF
2=E1 – CCS
3=E1 – CAS

ITY=
ITY?
ITY*
ITY#

ITY? ITY=x

(see Description of
Arguments)

Rx Backward
Alarms
Enable

RBA=

4 bytes, each a
value of 0 or 1

Command or Query.
(IDR Parameter)
Rx Backward Alarm enable:
0=Disable
1=External trigger Enable
Position indicates backward alarm numbers: 1234

Example: RBA=0101

RBA=
RBA?
RBA*
RBA#

RBA? RBA=xxxx

(see Description of
Arguments)

Rx Buffer
Size

RBS=

5 bytes

Command or Query.
Rx Buffer Size, 16 to 32768 bytes, in 2-byte steps, unless other
limitations apply (see Sect. 5.4.5 CONFIG: CLOCKS).

Example: RBS=08192 (selects 8192 bytes)

RBS=
RBS?
RBS*
RBS#

RBS? RBS=xxxxx

(see Description of
Arguments)

Rx Clock
Source

RCK=

1 byte, value of
0 thru 3

Command or Query.
Rx Clock Source (for data rate accuracy), where:

0=Rx Satellite
1=Tx-Terrestrial
2=External Clock
3=INSERT (Valid as a command only when Rx framing is Insert or
D&I++ and the interface is G.703 or set for D&I loop)

Example: RCK=1 (selects Tx-Terrestrial)

RCK=
RCK?
RCK*
RCK#

RCK? RCK=x

(see Description of
Arguments)