Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Spectrum
Invert
RSI=
1 byte, value of
0 or 1
Command or Query.
Rx Spectrum Invert, where:
0=Normal
1=Rx Spectrum Invert
Example: RSI=0 (selects Normal)
RSI=
RSI?
RSI*
RSI#
RSI? RSI=x
(see Description of
Arguments)
Rx Signal
Level
N/A 5
bytes
Query
Only.
Unit returns the value of the Rx signal level, in dBm, between –20 and
–60 dBm:
• If >-20dBm, returns RSL=GT-20 (GT means ‘greater than’)
• If in the range of –20 to –60dBm, returns RSL===-xx
• If <-60 dBm, returns RSL=LT-60 (LT means ‘less than’)
Example: RSL=== -45 (–45 dBm)
N/A RSL?
RSL=xxxxx
(see Description of
Arguments)
Rx Symbol
Rate
N/A 9
bytes,
numeric
Query only.
Returns the Rx symbol rate (shown on front panel), where in the form
ddddd.ddd
RSR?
RSR=
RSR? RSR=ddddd.ddd
(see Description of
Arguments)
Rx Demod
Acquisition
Sweep Width
RSW=
2 bytes
Command or Query.
Rx
± acquisition sweep range of demodulator, in kHz, ranging from
±1 to ±32 kHz.
Example: RSW=09 (selects
±9kHz)
RSW=
RSW?
RSW*
RSW#
RSW?
RSW=xx
(see Description of
Arguments)
Rx Ternary
Code
RTC=
1 byte, value of
0 thru 3
Command or Query.
(G.703 Parameter)
Rx Ternary Code, where:
0=AMI
1=B8ZS
2=B6ZS
3=HDB3
Example: RTC=1 (selects B8ZS)
RTC=
RTC?
RTC*
RTC#
RTC?
RTC=x
(see Description of
Arguments)
Receive
Terrestrial
Alarm Enable
RTE=
1 byte, value of
0 or 1
Command or Query.
(Insert mode parameter)
Receive Terrestrial Alarm Enable conditions, where:
0=Disables the alarm
1=Enables the alarm.
Example: RTE=0 (Alarm disabled).
RTE=
RTE?
RTE*
RTE#
RTE? RTE=x
(see Description of
Arguments)
Rx Audio
Volume
Control
RVL=
4 bytes
Command or Query.
(Audio/IDR Parameter)
Rx Audio Volume control, in the form aabb, where:
aa=Rx 1 volume control in dB, values defined below.
bb=Rx 2 volume control in dB, values defined below.
Valid values: -6, -4, -2, +0, +2, +4, +6, +8
Example: RVL= -2+4 (sets Rx 1 to –2 dB and Rx 2 to +4 dB)
RVL=
RVL?
RVL*
RVL#
RVL? RVL=aabb
(see Description of