8 select: store/load, 9 select: utilities, 1 utilities: set-rtc – Comtech EF Data CDM-600/600L User Manual
Page 118: 2 utilities: display-brightness

CDM-600/600L Open Network Satellite Modem
Revision 3
Front Panel Operation
MN/CDM600L.IOM
5–42
5.8
SELECT: STORE/LOAD
CONFIGURATION: 0 LOAD STORE
‘AVAILABLE’
The user can store up to 10 different modem configurations – 0 through 9. A location that is
available is noted on the bottom line as ‘AVAILABLE’.
Move the cursor to the configuration location number using the [
←][→] arrow keys. Edit the
value using the [
↑][↓] arrow keys. Next, select Load or Store using the [←][→] arrow keys, then
press [ENT].
As a modem configuration is stored, the time and date is recorded. This time and date information
is shown on the bottom line as the location number is edited.
STORE/LOAD: OVERRIDE CONFIGURATION
Whether storing into a location or loading into the working memory from a stored location, the
user is required to confirm the request, as information will be overwritten:
Configuration: XX OVERRIDE: NO (YES,NO)
14:06:37 26/10/06
Select the Override choice, YES or NO, using the [
↑][↓] arrow keys, then press [ENT].
5.9
SELECT: UTILITIES
UTILITIES: SET-RTC DISPLAY-BRIGHTNESS
LAMP 1:1-MANUAL-SWITCH EDIT-CIRCUIT-ID
Select Set-RTC, Display-Brightness, Lamp, 1:1-Manual-Switch, or Edit-Circuit-ID using the
[
←][→] arrow keys, then press [ENT]
.
5.9.1
UTILITIES: SET-RTC
EDIT REAL-TIME CLOCK:
TIME: 12:01:02 DATE: 26/10/06
To edit the time and date settings of the Real-Time Clock, select the digit to be edited using the
[
←][→] arrow keys, then edit the value of the digit using the [↑][↓] arrow keys. Press [ENT]
when done.
IMPORTANT
Note that in accordance with international convention, the date is shown in
DAY-MONTH-YEAR format.
5.9.2
UTILITIES: DISPLAY-BRIGHTNESS
EDIT DISPLAY BRIGHTNESS: