background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix E

MN/CDM600L.IOM

E–2

E.2

ODU Operations via Serial Remote Control

For a complete overview of Serial Remote Control and the commands and queries associated with
remote ODU configuration, operation, and monitoring, refer to Appendix D. SERIAL
REMOTE CONTROL
.

E.2.1 Remote Control Address Setup

The Outdoor Unit (ODU) connected to a CDM-600 Modem through FSK can be remotely
monitored and controlled by using ODU remote commands through Serial Remote or Telnet. The
address of the ODU is set up as follows:

For local-end ODUs:

o

Use Modem’s RC address + 1 for Standalone unit or Online unit in a 1:1 Redundancy

System.

o

Use Modem’s RC address + 2 for Offline unit in a 1:1 Redundancy System.

For distant-end ODUs in an EDMAC setup:

o

Use EDMAC Slave Address (ESA) Range + 4 for Standalone unit or Online unit in a

1:1 Redundancy System.

o

Use EDMAC Slave Address (ESA) Range + 5 for Offline unit in a 1:1 Redundancy

System.