F.3.4 (select:) odu (outdoor unit), F.3.4.1 odu: buc-fsk – Comtech EF Data CDM-600/600L User Manual

Page 255

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix F

MN/CDM600L.IOM

F–5

F.3.4

(SELECT:) ODU (Outdoor Unit)

ODU: BUC-FSK BUC-CONFIG BUC-LO
LNB-CONFIG LNB-LO

Select BUC-FSK, BUC-CONFIG, BUC-LO, LNB-CONFIG, or LNB-LO using the [

][]

arrow keys, then press [ENT]. The menu branch submenus are as follows:

BUC-FSK

If an FSK-capable BUC is employed, provides access to a further set of menus that
define the FSK setup, and use it for control and monitor.

BUC-CONFIG

If a BUC supply is installed, permits the user to configure BUC-related items.

BUC-LO

Allows setup to program Transmit frequency in terms of terminal uplink frequency
rather than modem IF output frequency. Entering a nonzero value for BUC LO will
cause the TX IF frequency programming under CONFIG: TX

Æ TX-IF to be entered

and displayed as the actual TX frequency for the satellite terminal.

LNB-CONFIG

If an LNB supply is installed, permits the user to configure LNB-related items.

LNB-LO

Allows setup to program Receive frequency in terms of terminal downlink frequency
rather than modem IF input frequency. Entering a nonzero value for LNB LO will
cause the RX IF frequency programming under CONFIG: RX

Æ RX-IF to be entered

and displayed as the actual RX frequency for the satellite terminal.

F.3.4.1 ODU: BUC-FSK

FSK: LINK =OFF TX–OUTPUT=N/A
LEVELING=N/A ADDRESS=N/A

Select a parameter to edit – LINK, TX-OUTPUT, LEVELING, or ADDRESS – using the
[

][] arrow keys, then use the [][] arrows keys to edit the settings for that parameter. Press

[ENT] when done. Observe the following:

LINK

To control FSK communications with the BUC, use the [

] [] arrow keys to select

communications as ON or OFF, then press [ENT] when done.

TX-OUTPUT

Disabled in LINK OFF position.
To control the TX RF output from the BUC, use the [

] [] arrow keys to select

output as ON or OFF, then press [ENT] when done.

LEVELING

Disabled in LINK OFF position.
To control the automatic BUC output power leveling loop, use the [

] [] arrow keys to

select the leveling as ON or OFF, then press [ENT] when done.

ADDRESS

Disabled in LINK OFF position.
To set the FSK address for the BUC, use the [

] [] arrow keys to assign an address

from 1 to 15, then press [ENT] when done.