beautypg.com

Comtech EF Data CDM-600/600L User Manual

Page 220

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix D

MN/CDM600L.IOM

D–28

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Faults and
Status (cont)

c = Rx Traffic status:

0=Rx Traffic OK
1=Demodulator unlocked
2=AGC Alarm - signal out of range
3=Demux Lock (Frame SYNC)
4=Spare
5=Buffer Slip
6=AIS detected on incoming data
7=Eb/No alarm

8=Buffer Clock activity

9=LNB current (CDM-600L)

A=LNB voltage (CDM-600L)
d = Open Network:

0=No Faults
1=Loss of Tx frame
2=BER Alarm
3=Loss of Tx multiframe
4=Tx signaling AIS
5=Tx Remote alarm
6=IBS satellite alarm
7=IDR Rx BWA1
8=IDR Rx BWA2
9=IDR Rx BWA3
A=IDR Rx BWA4
B=IDR Tx BWA1
C=IDR Tx BWA2
D=IDR Tx BWA3
E=IDR Tx BWA4

e = Change in fault status since last poll
f = Change in unit configuration since last poll

Rx BER

N/A

5 bytes

Query only.
Units returns the value of the estimated corrected BER in the form
a.b x 10

-c

. First three bytes are the value. Last two bytes are the

exponent. Returns 99999 if the demodulator is unlocked or BER
data is unavailable.

Example: BER=4.8E3 (BER=4.8 x 10

-3

)

N/A BER?

BER=a.bEc
(see Description of
Arguments)

Buffer Fill
State

N/A

2 bytes

Query only.
Unit returns the value of the buffer fill state, between 1 and 99%.
Returns 00 if demodulator is unlocked.

Example: BFS=33 (33%)

N/A BFS?

BFS=xx
(see Description
of Arguments)