Comtech EF Data CDM-600/600L User Manual
Page 220
![background image](https://www.manualsdir.com/files/778756/content/doc220.png)
CDM-600/600L Open Network Satellite Modem
Revision 3
Appendix D
MN/CDM600L.IOM
D–28
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Faults and
Status (cont)
c = Rx Traffic status:
0=Rx Traffic OK
1=Demodulator unlocked
2=AGC Alarm - signal out of range
3=Demux Lock (Frame SYNC)
4=Spare
5=Buffer Slip
6=AIS detected on incoming data
7=Eb/No alarm
8=Buffer Clock activity
9=LNB current (CDM-600L)
A=LNB voltage (CDM-600L)
d = Open Network:
0=No Faults
1=Loss of Tx frame
2=BER Alarm
3=Loss of Tx multiframe
4=Tx signaling AIS
5=Tx Remote alarm
6=IBS satellite alarm
7=IDR Rx BWA1
8=IDR Rx BWA2
9=IDR Rx BWA3
A=IDR Rx BWA4
B=IDR Tx BWA1
C=IDR Tx BWA2
D=IDR Tx BWA3
E=IDR Tx BWA4
e = Change in fault status since last poll
f = Change in unit configuration since last poll
Rx BER
N/A
5 bytes
Query only.
Units returns the value of the estimated corrected BER in the form
a.b x 10
-c
. First three bytes are the value. Last two bytes are the
exponent. Returns 99999 if the demodulator is unlocked or BER
data is unavailable.
Example: BER=4.8E3 (BER=4.8 x 10
-3
)
N/A BER?
BER=a.bEc
(see Description of
Arguments)
Buffer Fill
State
N/A
2 bytes
Query only.
Unit returns the value of the buffer fill state, between 1 and 99%.
Returns 00 if demodulator is unlocked.
Example: BFS=33 (33%)
N/A BFS?
BFS=xx
(see Description