Comtech EF Data CDM-600/600L User Manual

Page 48

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Introduction

MN/CDM600L.IOM

1–20

Tx On/Off ratio

CDM-600L:

-75 dBm maximum

CDM-600:

55 dB minimum

External TX Carrier
Off

By TTL 'low' signal or external contact closure - hardware function automatically overrides processor

Clocking options

CDM-600L:

Internal, ±1ppm or 0.02 ppm (SCT)

External, locking over a ±100 ppm range (TT)
Loop timing (Rx satellite clock) - supports asymmetric operation - Rx and Tx data rates do not need to
be identical
External Clock at Tx data rate.

CDM-600:

Internal, ±1.5ppm or 0.02 ppm (SCT)

External, locking over a ±100 ppm range (TT)
Loop timing (Rx satellite clock) - supports asymmetric operation - Rx and Tx data rates do not need to
be identical
External Clock

CDM-600 ONLY:

Output impedence

50

Ω and 75Ω, front panel selectable

21 dB minimum return loss

Output phase noise

< 0.48

0

rms double sided, 100 Hz to 1MHz

(minimum of 16 dB better overall than the INTELSAT IESS-308/309 requirement)

CDM-600L ONLY:

External Reference

1, 2, 5, 10, or 20 MHz @ 0 dBm to +20 dBm.
Internal reference phase locks to external reference.

BUC Reference
(10 MHz)


Phase Noise

On center conductor of L-Band output connector; 10.0 MHz

± 0.02 ppm (Optional 1ppm)

0.0 dBm,

± 3 dBm; programmable ON/OFF

Source: 1. Internal Modem Reference
2. External Reference (10 MHz)
dB/Hz Frequency

Offset

-80

1 Hz

-110

10

Hz

-135

100

Hz

-140

1

kHz

-150

10

kHz

-150

100

kHz

Output Phase Noise

dB/Hz Frequency

Offset

-63.0 100

Hz

-73.0 1

kHz

-83.0 10

kHz

-93.0 100

kHz

Fundamental AC line spurious is -42 dBc or lower
The sum of all other single sideband spurious, from 0 to 0.75 x symbol rate, is -48 dBc or lower

BUC Supply Voltage

(Suppplied through Tx
IF center conductor and
selectable ON/OFF via
M&C control)

Standard unit has no BUC supply.
Optional BUC Supply:

24VDC, 4.0 Amps maximum, 100W

48VDC, 3.75 Amps maximum, 180W

BUC Current
Monitor

Min/Max programmable current alarm thresholds.

BUC Monitoring
(FSK ON)

Power level, temperature, power class, PLL lock.

BUC Power
Leveling (FSK ON)

Modem levels BUC output power by increasing or decreasing carrier output to match programmed
target level.

Tx Carrier ON Delay

Delay from power on to Tx IF output allowing BUC to warm up. Programmable 0 to 200 sec.