beautypg.com

Comtech EF Data CDM-600/600L User Manual

Page 204

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix D

MN/CDM600L.IOM

D–12

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

TX LO
Frequency

(CDM-600L ONLY)

TLO=

6 bytes

Command or Query.
BUC transmit LO frequency information in the form: xxxxxs, where:
xxxxx is the LO frequency in the range of 3000 to 65000 MHz
or 0=OFF
s=sign for the MIX

Note: For additional information refer to Appendix G. BUC FSK
COMMUNICATION
; LO, MIX , and Spectrum Settings.

Terminal Frequency = BUC LO

± TFQ

TLO=
TLO?
TLO*
TLO#

TLO? TLO=xxxxxs

(see Description of
Arguments)

Tx Power
Level

TPL=

4 bytes

Command or Query.
NOTE: COMMAND NOT VALID IN AUPC MODE.

TPL=
TPL?
TPL*
TPL#

TPL?

TPL=xx.x
(see Description of
Arguments)

FOR CDM-600L:
Tx Output power level between 0 and -45 dBm in the form xx.x (minus
sign assumed). [Beyond –40 dBm exceeds the specification].

Example: TPL=13.4

Note: When Output Power Leveling is enabled, power level configuration
is not allowed, and this command is rejected. Response will be TPL*. The
response to the query TPL? will be the adjusted leveled value.

WHEN EXTERNAL 20dB ATTENUATOR IS PRESENT ON CDM-600L:
The power level indicated is the final power after the attenuator, if the
External 20dB Attenuator is present.

IN MANUAL (Normal) POWER MODE (AUP=0): Tx Output power level
may be configured between -45 and 0 dBm. [Between -45 and -40 dBm
exceeds the specification.]

IN MANUAL-LOW (Low Power) MODE (AUP=2): Tx Output power level
may be configured between -65 and -20 dBm in the form xx.x (minus sign
assumed). [Between -65 and -60 dBm exceeds the specification. The
power levels exceeding the specification are indicated on the front panel
menu by a

*

.]

See Appendix J. KT/11202-1 STEP ATTENUATOR KIT for further details.
FOR CDM-600:
Tx Output power level between 0 and -20 dBm (minus sign assumed).
Example: TPL=13.4

Tx
Reed-
Solomon
Encoding

TRS=

1 byte, value of
0 to 3

Command or Query.
Tx RS encoding

0=Normal (based on the Open Network framing mode selected)
1=IESS-310 mode – Available all framing modes, except EDMAC.
2=EF Data legacy standard (225,205) – Unframed only
3=IBS (126,112) – Unframed only

Available all framing modes, except EDMAC (this is a ‘don’t care’ if no
RS is selected under FEC Type)

Example: TRS=0

TRS=
TRS?
TRS*
TRS#

TRS? TRS=x

(see Description of