D.6.7 lnb commands and queries (cdm-600l only) – Comtech EF Data CDM-600/600L User Manual

Page 228

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix D

MN/CDM600L.IOM

D–36

D.6.7 LNB Commands and Queries (CDM-600L ONLY)

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

LNB Power
Control

LNB=

1 byte

Command or Query.
Selects LNB DC Power Supply, where:
0=OFF
1=ON

LNB=
LNB?
LNB*
LNB#

LNB? LNB=x

(see Description of
Arguments)

LNB Current

N/A

4 bytes

Query only.
Unit returns LNB current value in mA.

N/A LNC?

LNC=xxxx
(see Description of
Arguments)

LNB High
current limit

LNH=

3 bytes

Command or Query.
Sets LNB High Current Limit, in mA, in the form xxx, where:
xxx=a value between 0 and 500

LNH=
LNH?
LNH*
LNH#

LNH? LNH=xxx

(see Description of
Arguments)

LNB Low
current limit

LNL=

3 bytes

Command or Query.
Sets LNB Low Current Limit, in mA, in the form xxx, where:
xxx=a value between 0 and 500

LNL=
LNL?
LNL*
LNL#

LNL? LNL=xxx

(see Description of
Arguments)

LNB
Reference
Enable

LNR=

1 byte, value of
0 or 1

Command or Query.
Selects LNB 10 MHz Reference, where:
0=Disable LNB Reference
1=Enable LNB Reference

LNR=
LNR?
LNR*
LNR#

LNR? LNR=x

(see Description of
Arguments)

LNB Voltage

LNV=

1 byte, value of
0, 1, or 2

Command or Query.
Sets the LNB Voltage, where:

0=13V LNB Voltage
1=18V LNB Voltage
2=24V LNB Voltage

LNV=
LNV?
LNV*
LNV#

LNV? LNV=x

(see Description of
Arguments)