beautypg.com

Comtech EF Data CDM-600/600L User Manual

Page 216

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix D

MN/CDM600L.IOM

D–24

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Retrieve next
5 unread
Stored
Statistics

N/A

135 bytes

Query only.
Unit returns the oldest 5 Stored Statistics, which have not yet been
read over the remote control, in the reply form:[CR]Sub-body[CR]
Sub-body[CR]Sub-body[CR]Sub-body[CR]Sub-body;
Sub-body = AA.ABB.BC.CD.Dddmmyyhhmmss, where:

AA.A = Minimum Eb/No during sample period.
BB.B = Average Eb/No during sample period.
C.C = Max. Tx Power Level Increase during sample period.
D.D = Average Tx Power Level Increase during sample period.
ddmmyyhhmmss = date/time stamp.

If there are less than 5 statistics to be retrieved, the remaining positions
are padded with zeros. If there are no new events, the unit replies with
RNS*.

N/A RNS?

RNS=[CR]AA.ABB.BC.C
D.Dddmmyyhhmmss[CR]
AA.ABB.BC.CD.Dddmmy
yhhmmss[CR]AA.ABB.B
C.CD.Dddmmyyhhmmss[
CR]AA.ABB.BC.CD.Ddd
mmyyhhmmss[CR]AA.AB
B.BC.CD.Dddmmyyhhm
mss
(see Description of
Arguments)

ESC
parameters

SCP= 2

bytes,

numeric

Command or Query.
(IBS and ESC++ parameter)
Allows control of the ESC baud rate and character format, where x is
the ESC baud rate:
0=1200 baud
1=2400 baud
2=4800 baud
3=9600 baud
4=19200 baud
5=38400 baud
6=14400 baud
7=28800 baud

and y is the character format (data bits, parity bits, stop bits):
0= 8-N-1 (parity=none)
1= 7-E-2 (parity=even)
2= 7-O-2 (parity=odd)

The ESC baud rate breakpoints (determined by data rate) are shown
in Chapters 5 and 10. A response of SCP* will indicate if the data rate
will not allow a selected baud rate to operate.

SCP=
SCP?
SCP*
SCP#

SCP? SCP=xy

Statistics
Sample
Interval

SSI=

1 byte,
numerical

Command or Query.
Used to set the sample interval for the Statistics Logging Function, in 10-
minute increments, in the form x, where:

x= 0-9

Note: Setting this parameter to 0 disables the statistics logging function.

Example: SSI=3 means 30 minutes

SSI=
SSI?
SSI*
SSI#

SSI? SSI=x

(see Description of
Arguments)