Comtech EF Data CDM-600/600L User Manual
Page 216

CDM-600/600L Open Network Satellite Modem
Revision 3
Appendix D
MN/CDM600L.IOM
D–24
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Retrieve next
5 unread
Stored
Statistics
N/A
135 bytes
Query only.
Unit returns the oldest 5 Stored Statistics, which have not yet been
read over the remote control, in the reply form:[CR]Sub-body[CR]
Sub-body[CR]Sub-body[CR]Sub-body[CR]Sub-body;
Sub-body = AA.ABB.BC.CD.Dddmmyyhhmmss, where:
AA.A = Minimum Eb/No during sample period.
BB.B = Average Eb/No during sample period.
C.C = Max. Tx Power Level Increase during sample period.
D.D = Average Tx Power Level Increase during sample period.
ddmmyyhhmmss = date/time stamp.
If there are less than 5 statistics to be retrieved, the remaining positions
are padded with zeros. If there are no new events, the unit replies with
RNS*.
N/A RNS?
RNS=[CR]AA.ABB.BC.C
D.Dddmmyyhhmmss[CR]
AA.ABB.BC.CD.Dddmmy
yhhmmss[CR]AA.ABB.B
C.CD.Dddmmyyhhmmss[
CR]AA.ABB.BC.CD.Ddd
mmyyhhmmss[CR]AA.AB
B.BC.CD.Dddmmyyhhm
mss
(see Description of
Arguments)
ESC
parameters
SCP= 2
bytes,
numeric
Command or Query.
(IBS and ESC++ parameter)
Allows control of the ESC baud rate and character format, where x is
the ESC baud rate:
0=1200 baud
1=2400 baud
2=4800 baud
3=9600 baud
4=19200 baud
5=38400 baud
6=14400 baud
7=28800 baud
and y is the character format (data bits, parity bits, stop bits):
0= 8-N-1 (parity=none)
1= 7-E-2 (parity=even)
2= 7-O-2 (parity=odd)
The ESC baud rate breakpoints (determined by data rate) are shown
in Chapters 5 and 10. A response of SCP* will indicate if the data rate
will not allow a selected baud rate to operate.
SCP=
SCP?
SCP*
SCP#
SCP? SCP=xy
Statistics
Sample
Interval
SSI=
1 byte,
numerical
Command or Query.
Used to set the sample interval for the Statistics Logging Function, in 10-
minute increments, in the form x, where:
x= 0-9
Note: Setting this parameter to 0 disables the statistics logging function.
Example: SSI=3 means 30 minutes
SSI=
SSI?
SSI*
SSI#
SSI? SSI=x
(see Description of
Arguments)