E.3.3.1.3.4 ODU SELECT: INFORMATION
INFO: MODEL TX RX MISC LNA
This menu provides the user with access to read-only information displays on the ODU as
configured for operation. Select MODEL, TX, RX, MISC, or LNA using the [
←][→] arrow
keys, then press [ENT].
The following INFORMATION display examples are intended for reference only – the
information and values displayed in each example may differ, depending on the configuration in
use. After viewing each information screen, press [ENT] or [CLR] to return to previous menu.
INFORMATION: MODEL
MODEL: CSAT-5060/025 V2.19
S/N: 010300346
Per the example shown, this read-only display provides the model, serial number, and firmware
version for the ODU in use.
INFORMATION: TX
INFO: TX:OFF 6427.0MHz 23.00dB
AMP:OFF UNMUTED SLOPE:0.3
Per the example shown, this read-only display provides information on the CSAT transmitter status:
Tx operating state (ON or OFF), Tx Frequency, Tx Attenuation, Amplifier state (ON or OFF), Tx
Mute state (Muted or Unmuted), and Tx Slope adjustment.
INFORMATION: RX
INFO: RX:ON 3400.0MHz 18.00dB
REF:087 UNMUTED SLOPE:0.2
Per the example shown, this read-only display provides information on the CSAT receiver status: Rx
operating state (ON or OFF), Rx Frequency, Rx Attenuation, Rx Mute state (Muted or Unmuted),
and Rx Slope adjustment.
INFORMATION: MISC
INFO: COLD START:OFF
AUTO FAULT RECOVERY:ENABLED
Per the example shown, this read-only display provides the current state of the Cold Start (ON or
OFF) and the Auto Fault Recovery function (ENABLED or DISABLED).