Comtech EF Data CDM-600/600L User Manual
Page 261
CDM-600/600L Open Network Satellite Modem
Revision 3
Appendix G
MN/CDM600L.IOM
G–3
G.2 Message Structure
G.2.1
Command Message Structure (CDM-600L to BUC)
Byte
Name
Description
Value
1
Address
Address of BUC
0x01 to 0x0f
2 Command
Request Status
Tx On/Off
Change Address
Set Carrier Frequency
0x01
0x02
0x03
0x04
3
Data Byte 1
Not used if command:
= 0x01
Tx control if command:
= 0x02
New address if command:
= 0x03
Carrier Frequency if command:
= 0x04
0xAA
0=Off, 1=On
0x01 to 0x0f
MSbyte
4
Data Byte 2
Not used if command:
= 0x01
Not used if command:
= 0x02
Not used if command:
= 0x03
Carrier Frequency if command:
= 0x04
0XAA
0xAA
0xAA
LSbyte
5
Data Byte 3
Not Used
0xAA
6
Data Byte 4
Not Used
0xAA
7
Checksum
Algebraic sum of bytes 1 - 6
G.2.2
Response Message Structure (BUC to CDM-600L)
Byte
Name
Description
Value
1
Address
Address of BUC shifted left by 4
0x10 to 0xf0
2
Level Byte 1
MSbyte of TX output power
3
Level Byte 2
LSbyte of TX output power
4 Temperature Temperature in
°C
5
Status Byte 1
Bit 0: Temperature out-of-range
Bit 1: PLL out-of-lock
Bit 2: Checksum error
Bit 3: TX Status
Bits 4 thru 7: Power Class
1: OOR, 0: Normal
1: OOL, 0: Normal
1: error in command
message, 0: Normal
1: TX ON, 0: TX Off
0x1 to 0xf
6
Status Byte 2
Bits 0 – 3: Not used
Bits 4 –7: Software version
0xAA
0x0 to 0xf
7
Checksum
Algebraic sum of bytes 1 - 6
Data Field Definitions
TX Power Level
Unsigned integer in 1/100 dBm
Carrier Frequency
Unsigned integer in MHz.
Termperature
Signed character in
°C