E.3.3.1 (SELECT:) ODU (CSAT-5060 Transceiver)

ODU CONTROL=ENABLE (DISABLE/ENABLE)
SYSTEM TYPE=STANDALONE (STANDALONE,1:1)

Select the parameter to edit – ODU CONTROL or SYSTEM TYPE – using the [

][] arrow

keys, then use the [

][] arrow keys to modify that parameter setting. Press [ENT] when done.

Observe the following:

ODU CONTROL:
DISABLE, ENABLE

DISABLE Turns OFF the FSK link to the ODU.

ENABLE Turns ON the FSK link to the ODU. Once the FSK link to the ODU
is enabled, the CDM-600 senses the active ODU model and automatically
adjusts the front panel menu displays specific for that product (i.e.,
CSAT-5060 or KST-2000A/B).

SYSTEM TYPE:
STANDALONE, 1:1

Select STANDALONE when the CDM-600 is linked via the Rx IF cable to a
single (standalone) Comtech EF Data CSAT-5060 ODU.

Select 1:1 when the CDM-600 is linked to a redundant CSAT-5060 system
via connection between the Rx IF and the ODU Redundancy Controller Box.

IMPORTANT

When the following menu selections are made:

ODU

Æ

ENABLE

Æ

SYSTEM TYPE=STANDALONE

ODU

Æ

ENABLE

Æ

SYSTEM TYPE=1:1

Æ

ODU#1

ODU

Æ

ENABLE

Æ

SYSTEM TYPE=1:1

Æ

ODU#2

The user is directed to a common ODU SELECT submenu branch:

SELECT: CONFIGURATION MONITOR ALARMS
INFORMATION

For clarity, this common submenu branch is defined in detail in Sect. 3.3.1.3.

E.3.3.1.1

ODU: ENABLE

Æ SYSTEM TYPE=STANDALONE

SELECT: CONFIGURATION MONITOR ALARMS
INFORMATION

Select CONFIGURATION, MONITOR, ALARMS, or INFORMATION using the [

][]

arrow keys, then press [ENT].

The selections for this common submenu branch are defined in detail in Sect. 3.3.1.3.

E.3.3.1.2

ODU: ENABLE

Æ SYSTEM TYPE=1:1

1:1 MONITOR & CONTROL:
ODU#1 ODU#2 REDUNDANCY-BOX

For Monitor/Control of a redundant CSAT-5060 system, select ODU#1, ODU#2, or REDUNDANCY-
BOX
using the [

][] arrow keys, then press [ENT].