CONFIGURATION

Æ TX-PARAMETERS Æ SLOPE

TX SLOPE: MODE=MANUAL (MANUAL,CAL)
SLOPE=0.3 (0.0 - 1.0)

Select MANUAL or CALIBRATED using the [

][] arrow keys. If Manual mode

is selected, the slope may be edited. Select the digit to edit using the [

][] arrow

keys, then use the [

][] arrow keys to modify that digit. Press [ENT] when done, or

[CLR] to cancel the edit and return to the previous menu.

CONFIGURATION

Æ RX-PARAMETERS

RX: FREQ=3600.0 MHz ATT=18.00 dB
MUTE=UNMUTED SLOPE

Select the parameter to edit – FREQ, ATT, AMP, MUTE, or SLOPE – using the
[

][] arrow keys, then use the [][] arrow keys to modify that parameter setting.

Press [ENT] when done. Observe the following:

FREQ

(Frequency) Edit the Rx frequency by first selecting the digit to be edited using
the [

][] arrow keys, then changing the value of that digit using the [][]

arrow keys. Press [ENT] when done or [CLR] to cancel the edit and return to
the previous menu.

ATT

(Attenuation) Edit the Rx attentuation by first selecting the digit to be edited
using the [

][] arrow keys, then changing the value of that digit using the

[

][] arrow keys. Press [ENT] when done.

MUTE

(ODU Rx Mute State ) Select as MUTED or UNMUTED.

SLOPE

Slope parameters are edited as per the information that follows.

CONFIGURATION

Æ RX-PARAMETERS Æ SLOPE

RX SLOPE: MODE=MANUAL (MANUAL,CAL)
SLOPE=0.2 (0.0 - 1.0)

Select MANUAL or CALIBRATED using the [

][] arrow keys. If Manual mode

is selected, the slope may be edited. Select the digit to edit using the [

][] arrow

keys, then use the [

][] arrow keys to modify that digit. Press [ENT] when done, or

[CLR] to cancel the edit and return to the previous menu.

CONFIGURATION

Æ LNA-PARAMETERS

LNA: STATE=OFF CALIBRATE-LNA-CURRENT=NO
CURRENT-WINDOW=48% FAULT-LOGIC=SUMMARY

Select the parameter to edit – STATE, CALIBRATE-LNA-CURRENT, CURRENT-
WINDOW
, or FAULT-LOGIC – using the [

][] arrow keys, then use the [][]

arrow keys to modify that parameter setting. Press [ENT] when done. Observe the
following: