Configuration ( tx-parameters ( slope, Configuration ( rx-parameters, Configuration ( rx-parameters ( slope – Comtech EF Data CDM-600/600L User Manual
Page 241: Configuration ( lna-parameters, Configuration æ tx-parameters æ slope, Configuration æ rx-parameters, Configuration æ rx-parameters æ slope, Configuration æ lna-parameters
CDM-600/600L Open Network Satellite Modem
Revision 3
Appendix E
MN/CDM600L.IOM
E–11
CONFIGURATION
Æ TX-PARAMETERS Æ SLOPE
TX SLOPE: MODE=MANUAL (MANUAL,CAL)
SLOPE=0.3 (0.0 - 1.0)
Select MANUAL or CALIBRATED using the [
↑][↓] arrow keys. If Manual mode
is selected, the slope may be edited. Select the digit to edit using the [
←][→] arrow
keys, then use the [
↑][↓] arrow keys to modify that digit. Press [ENT] when done, or
[CLR] to cancel the edit and return to the previous menu.
CONFIGURATION
Æ RX-PARAMETERS
RX: FREQ=3600.0 MHz ATT=18.00 dB
MUTE=UNMUTED SLOPE
Select the parameter to edit – FREQ, ATT, AMP, MUTE, or SLOPE – using the
[
←][→] arrow keys, then use the [↑][↓] arrow keys to modify that parameter setting.
Press [ENT] when done. Observe the following:
FREQ
(Frequency) Edit the Rx frequency by first selecting the digit to be edited using
the [
←][→] arrow keys, then changing the value of that digit using the [↑][↓]
arrow keys. Press [ENT] when done or [CLR] to cancel the edit and return to
the previous menu.
ATT
(Attenuation) Edit the Rx attentuation by first selecting the digit to be edited
using the [
←][→] arrow keys, then changing the value of that digit using the
[
↑][↓] arrow keys. Press [ENT] when done.
MUTE
(ODU Rx Mute State ) Select as MUTED or UNMUTED.
SLOPE
Slope parameters are edited as per the information that follows.
CONFIGURATION
Æ RX-PARAMETERS Æ SLOPE
RX SLOPE: MODE=MANUAL (MANUAL,CAL)
SLOPE=0.2 (0.0 - 1.0)
Select MANUAL or CALIBRATED using the [
↑][↓] arrow keys. If Manual mode
is selected, the slope may be edited. Select the digit to edit using the [
←][→] arrow
keys, then use the [
↑][↓] arrow keys to modify that digit. Press [ENT] when done, or
[CLR] to cancel the edit and return to the previous menu.
CONFIGURATION
Æ LNA-PARAMETERS
LNA: STATE=OFF CALIBRATE-LNA-CURRENT=NO
CURRENT-WINDOW=48% FAULT-LOGIC=SUMMARY
Select the parameter to edit – STATE, CALIBRATE-LNA-CURRENT, CURRENT-
WINDOW, or FAULT-LOGIC – using the [
←][→] arrow keys, then use the [↑][↓]
arrow keys to modify that parameter setting. Press [ENT] when done. Observe the
following: