xviii
acceptable connector ratings include VDE, NF-USE, UL, CSA, OVE, CEBEC, NEMKO,
DEMKO, BS1636A, BSI, SETI, IMQ, KEMA-KEUR and SEV.
International Symbols
Symbol
Definition
Symbol
Definition
~
Alternating Current
Protective Earth
Fuse
Chassis Ground
CDM-600L DC Modem Installation: The DC input CDM-600L is connected to a nominal 48
VDC prime power source. The DC input is isolated from the chassis and from the DC output to
the BUC if equipped with internal BUC power supply. The chassis may be connected to a local
system ground using a separate wire to the ground stud on the back of the chassis. Since the DC
input is isolated, either the positive or the negative side of the DC input may be common with
local ground. Labeling on the back of the chassis indicates the positive and negative terminals of
the input power socket.
The modem is supplied with a 2-wire power cable (CEFD part number CA/WR10327-1) with one
end terminated with a connector that mates with the modem input power socket. Positive DC
input is on the red wire, while negative DC input is on the black wire. The DC input connector is
Molex PN 03-12-1026 with Molex PN 08-12-1222 pins.
Telecommunications Terminal Equipment Directive
In accordance with the Telecommunications Terminal Equipment Directive 91/263/EEC, this
equipment should not be directly connected to the Public Telecommunications Network.
EMC (Electromagnetic Compatibility)
In accordance with European Directive 89/336/EEC, the CDM-600/600L Modem has been
shown, by independent testing, to comply with the following standards:
Emissions:
EN 55022 Class B - Limits and methods of measurement of radio
interference characteristics of Information Technology Equipment.
(Also tested to FCC Part 15 Class B)
Immunity:
EN 50082 Part 1 - Generic immunity standard, Part 1: Domestic,
commercial and light industrial environment.
Additionally, the CDM-600/600L has been shown to comply with the following standards:
EN 61000-3-2
Harmonic Currents Emission
EN 61000-3-3
Voltage Fluctuations and Flicker
EN 61000-4-2
ESD
Immunity
EN 61000-4-4
EFT Burst Immunity
EN 61000-4-5
Surge
Immunity
EN 61000-4-6
RF Conducted Immunity
EN 61000-4-8
Power frequency Magnetic Field Immunity