E.3.3.1.3.2 ODU SELECT: MONITOR
MONITOR: TRANSMIT RECEIVE MISCELLANEOUS
POWER-SUPPLIES
This menu provides the user with access to real-time, read-only information displays on the ODU
currently in operation. Select TRANSMIT, RECEIVE, MISCELLANEOUS or POWER-
SUPPLIES using the [
↑][↓] arrow keys, then press [ENT].
MONITOR: TRANSMIT
TX: SYNTUNE = 09.6 VDC POWER = <24 dBm
IFLO = 11.1 VDC TEMP = 26 C
Per the example shown, this read-only display provides the Tx Synthesizer and IFLO tuning
voltages, the RF Output Power in dBm and the Transmitter temperature. Press [ENT] or [CLR]
to return to the previous menu.
MONITOR: RECEIVE
RX: SYNTUNE = 01.4 VDC
IFLO = 11.2 VDC TEMP = 26 C
Per the example shown, this read-only display provides the Rx Synthesizer and IFLO tuning
voltages and the Receiver temperature. Press [ENT] or [CLR] to return to the previous menu.
MONITOR: MISCELLANEOUS
MISC: REF TUNE = 03.0 VDC
LNA = 00.05 mA FAN = 550 mA
Per the example shown, this read-only display provides the Internal Reference Oscillator tuning
voltages, the LNA Current in milliamps and the Fan Current in milliamps. Press [ENT] or [CLR]
to return to the previous menu.
MONITOR: POWER-SUPPLIES
24V=24.1 VDC 12V=12.5VDC +5V=+5.4VDC
20V=21.2 VDC 10V=10.2VDC -5V=-5.3VDC
Per the example shown, this read-only display provides a monitor for the six internal power supplies.
Press [ENT] or [CLR] to return to the previous menu.