beautypg.com

F.3.4.4 odu: lnb-config, F.3.4.5 odu: lnb-lo – Comtech EF Data CDM-600/600L User Manual

Page 257

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix F

MN/CDM600L.IOM

F–7

F.3.4.4 ODU: LNB-CONFIG

LNB: VOLTAGE=13VOLT POWER=OFF 10MHz=OFF
ALARM-LOW = 000mA ALARM-HIGH = 500mA

Select a parameter to edit – POWER, 10MHz, ALARM-LOW, ALARM-HIGH, or
CAR-DELAY MIN:SEC – using the [

][] arrow keys, then use the [][] arrows keys to edit

the settings for that parameter. Press [ENT] when done. Observe the following:

VOLTAGE

To set the voltage for the LNB power supply, use the [

] [] arrow keys to select

13VOLT, 18VOLT, or 24VOLT, then press [ENT] when done.

POWER

To control LNB operation, use the [

] [] arrow keys to select power as ON or OFF,

then press [ENT] when done.

10 MHz

To control the 10MHz Reference output to the LNB, use the [

] [] arrow keys to

select the 10MHz Reference output as ON or OFF, then press [ENT] when done.

ALARM-LOW

To set the LNB low current alarm threshold, use the [

] [] arrow keys to set the

threshold (in mA), then press [ENT] when done.

ALARM-HIGH

To set the LNB high current alarm threshold, use the [

] [] arrow keys to set the

threshold (in mA), then press [ENT] when done.

F.3.4.5 ODU: LNB-LO

LNB-LO: FREQUENCY = 00000 MHz
MIX = HIGH (-)

Select Frequency or Mix using the [

][] arrow keys, then press [ENT] to continue. Observe the

following:

FREQUENCY

To set the lockout frequency in the LNB for the downconversion, use the [

] []

arrows keys to select a digit to edit, then the [

] [] arrow keys to adjust the value of

that digit. Press [ENT] when done.

Note that entering a nonzero value for the LNB lockout frequency will cause the RX
IF frequency programming under CONFIG: RX

Æ RX-IF to be entered and displayed

as the actual RX frequency for the satellite terminal.

MIX

To set the polarity for the upconversion mix in the LNB, use the [

] [] arrow keys to

select HIGH (-) for high side inverting mix, or LOW (+) for low side noninverting mix.