Comtech EF Data CDM-600/600L User Manual

Page 215

background image

CDM-600/600L Open Network Satellite Modem

Revision 3

Appendix D

MN/CDM600L.IOM

D–23

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Outdoor Unit
Comms
enable

ODU=

1 byte, value of
0 or 1

Command or Query.
Enables or disables communications, via the FSK link, with a
compatible Comtech EF Data outdoor unit (ODU), where:
0=Disabled
1=Enabled

Example: ODU=0 (Disabled)

ODU=
ODU?
ODU*
ODU#

ODU? ODU=x

(see Description of
Arguments)

ReCenter
Buffer

RCB= None Command

only

Forces the software to recenter the Rx Plesiochronous/Doppler buffer.

Example: RCB=

Note: This command takes no arguments.

RCB=
RCB?
RCB*
RCB#

N/A N/A

Retrieve next
5 unread
Stored Events

N/A

80 bytes

Query only.
Unit returns the oldest 5 Stored Events which have not yet been read
over the remote control, in the reply form [CR]Sub-body[CR]Sub-
body[CR]Sub-body[CR]Sub-body[CR]Sub-body;
Sub-body = ABCddmmyyhhmmss, where:
A being the fault/clear indicator.
F = Fault
C = Clear
I = Info
B being the fault type where:
1 = Unit
2 = Rx Traffic
3 = Tx Traffic
4 = Power on/off, or log cleared
5 = Open Network
C is Fault Code number (as in FLT?) or Info Code, which is:

0 = Power Off
1 = Power On
2 = Log Cleared
3 = Global Config Change
4 = Redundancy Config Change

If there are less than 5 events to be retrieved, the remaining positions are
padded with zeros. If there are no new events, the response is RNE*.

N/A RNE?

RNE=[CR]ABCddmmyyh
hmmss[CR]ABCddmmyy
hhmmss[CR]ABCddmmy
yhhmmss[CR]ABCddmm
yyhhmmss[CR]ABCddm
myyhhmmss

(see Description of
Arguments)