D.6.6 BUC Commands and Queries (CDM-600L ONLY)
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
BUC Address
OAD=
1 byte, value of
1 to 15
Command or Query.
Sets BUC Address, in the form xx, where:
xx= a value between 1 and 15.
Note: Valid only when the FSK and BUC power are enabled.
OAD=
OAD?
OAD*
OAD#
OAD? OAD=xx
(see Description of
Arguments)
BUC Current
N/A
4 bytes
Query only.
Unit returns the value of the BUC Current, in mA, in the form xxxx,
where:
xxxx=a value between 0 and 9999
Note: Unit returns 0000 when BUC power is turned OFF.
N/A ODC?
ODC=xxxx
(see Description of
Arguments)
BUC High
Current Limit
ODH=
4 bytes
Command or Query.
Sets BUC High Current Limit, in mA, in 100mA increments,in the
form xxxx, where:
xxxx= a value between 0 and 4000.
ODH=
ODH?
ODH*
ODH#
ODH? ODH=xxxx
(see Description of
Arguments)
BUC Low
Current Limit
ODL=
4 bytes
Command or Query.
Sets BUC Low Current Limit, in mA, in 100mA increments, in the
form xxxx, where:
xxxx= a value between 0 and 4000.
ODL=
ODL?
ODL*
ODL#
ODL? ODL=xxxx
(see Description of
Arguments)
BUC Power
enable
ODP=
1 byte, value of
0 or 1
Command or Query.
Selects BUC operation, where:
0=Disable BUC DC Power Supply
1=Enable BUC DC Power Supply
ODP=
ODP?
ODP*
ODP#
ODP? ODP=x
(see Description of
Arguments)
BUC 10 MHz
Reference
ODR=
1 byte
Command or Query.
Selects BUC 10 MHz Reference, where:
0=OFF
1=ON
ODR=
ODR?
ODR*
ODR#
ODR? ODR=x
(see Description of
Arguments)
BUC
Temperature
N/A
4 bytes
Query only.
Unit returns BUC temperature in the form sxxx, where:
s=sign
xxx=number
Note: Valid only when the FSK and BUC power are turned On.
N/A ODT?
ODT=sxxx
(see Description of
Arguments)
BUC Voltage
N/A
4 bytes
Query only.
Unit returns the value of the BUC Voltage, in volts, in the form xx.x,
where:
xx.x= a value between 0 and 64.0.
N/A
ODV?
ODV=xx.x
(see Description of
Arguments)
BUC Phase
Lock Loop
N/A
1 byte, value of
0 or 1
Query only.
Unit returns BUC phase lock loop, where:
0=Locked
1=Unlocked
Note: Valid only when the FSK and BUC power are turned On.
N/A OLL?
OLL=x
(see Description of
Arguments)